Address 341 Disabled tube at position A, B, C or D
Range = 0 - 31
Range value = the sum of the codes, where:
1 / 2 / 4 / 8 = tube A / B / C / D
If necessary, use the Route Alpha 250 terminal to enable the tube.
Address 342 EEPROM Errors (i) READ ONLY
Range = 0 - 15
.Range value = the sum of the codes, where:
1 = Page 0 EEPROM error. Fatal error. Contact your MEI
distributor.
2 = Page 1 EEPROM error. Fatal error. Contact your MEI
distributor.
4 = Audit FEM corrupt. Fatal error. Contact your MEI distributor.
8 = Audit FEM removed. Switch off power to the machine. Check
that audit FEM is inserted firmly in the board. Contact your
MEI distributor if the error persists.
CAUTION. Switch off the power to the changegiver for
at least
2 minutes
before inserting or removing the audit FEM. Failure to do this can cause
corruption of the FEM and
loss of audit data.
Address 343 EEPROM Errors (ii) READ ONLY
Range = 0 - 15
Range value = the sum of the codes, where:
1 = Incorrect configuration version. Contact your MEI distributor.
2 = Audit FEM not initialised. Initialise FEM, if fitted. Refer to the
Product Maintenance Handbook before attempting to
initialise the FEM. Contact your MEI distributor if the error
persists.
4 = Not used.
8 = Internal EEPROM write error. Contact your MEI distributor.