530.PROD.GB.3 : 530.INST.FFIND.NONE.NONE.GB.1 Black 60
60©, MEI., 1994.
CashFlow
530 Changegiver Product Maintenance Handbook
Problem Causes Actions
No coins
accepted
Blocked accept gate
opto’s, or build up of dirt in
the unit.
Power loom not inserted
correctly.
Switch off power to machine, check if the opto’s are blocked, and clean the unit.
Refer to the Product Maintenance Handbook before cleaning the opto’s.
Switch off power to the machine, and check the loom.
Poor coin
acceptance
Changegiver unit is not
level.
Modules are not mounted
and aligned correctly.
Build-up of dirt in the
acceptor.
Check and re-level the unit if necessary.
Check that the coin entry and exit chutes of the machine are aligned with the coin
entry cup on the unit and the cashbox on the machine.
Adjust the modules until they are aligned accurately.
Switch off power to machine, check and clean acceptor.
Coins are
accepted but
no credit is
given
Power loom is not
inserted correctly.
Coin jam in the separator
module (post gate
strobes are
covered).
Accept gate strobes
mechanism blocked or
dirty.
Switch off power to the machine, and check the loom.
Switch off power to the machine, and check the separator for jams.
Refer to the Product Maintenance Handbook before attempting to clean the
strobes or the opto’s.
Troubleshooting the CashFlow