Product specifications

530.PROD.GB.3 : 530.INST.FFIND.NONE.NONE.GB.1 Black 61
©, MEI., 1994.61
CashFlow
530 Changegiver Product Maintenance Handbook
Unit rejects
one type of
coin or token
Coin or token is inhibited.
Coin or token is damaged
or worn.
A tube has reached pre-
set float level, further
coins are rejected
because the unit is in float
mode.
Check the coin/token is in the coin set, and has been enabled.
Use the Route Alpha 250 terminal to enable the coin.
Discard the worn or damaged coin/token.
Press A to leave float mode and to clear any credit.
Check the tube levels, then make a vend to check that the correct change is
dispensed.
Coins are not
routing
correctly
The level of coins in a
tube is covering a top-
level sensor.
The top-level sensor
loom or the separator
loom is not connected
correctly.
Wrong acceptor or
separator is fitted.
A tube is disabled.
Check tube counts. If they are above the pre-set float levels and automatic tube
inventory is set, press Mode+A+C to float-down the coins in the tubes.
Switch off the power, remove the cassette and release the acceptor. Check that
the top-level sensor and separator looms are fitted correctly. Replace the acceptor
and cassette. Switch on power to the unit, insert coins and check routing.
Check that the acceptor and separator are the correct versions. Refer to your
authorised MEI distributor.
Use the Route Alpha 250 terminal to enable the tube.
Problem Causes Actions