CashFlow
530 Changegiver Product Maintenance Handbook
High-value
coins are
rejected and
exact change
light is ON
Too few coins in the
change tubes, leaving the
low-level sensors
uncovered.
Unit is in No Overpay
mode.
Re-float the coin tubes through the acceptor until the low-level sensor mirrors are
covered.
Check Route Alpha 250 address 242.
Incorrect
change is
dispensed
Insufficient change coins
are available.
Incorrect coin values are
set. Incorrect prices are
set for selections.
If required, float up through acceptor with correct change coins.
Check coin values and prices, reset if necessary using the Route Alpha 250
terminal. Press A, B, C and D to check if change coins are dispensed.
Check that coins are being routed to the tubes correctly.
No coins are
dispensed
Levels of coins in the
tubes are below the safe
count.
Dispenser loom not
connected, or loose.
Faulty dispenser module.
Check that change coins are available in the tubes. If necessary, float up the tubes
with the correct change coins.
Switch off power to the machine and check that the dispenser loom is fitted
correctly. Refer to the Product Maintenance Handbook.
Check that the dispenser module is operating correctly. Refer to the Product
Maintenance Handbook before you attempt to service or to replace the dispenser.
Red LED is
ON, except
when a vend
is made
Normal operation. No action.
Problem Causes Actions