Product specifications

530.PROD.GB.3 : 530.INST.FFIND.NONE.NONE.GB.1 Black 64
64©, MEI., 1994.
CashFlow
530 Changegiver Product Maintenance Handbook
Red LED is
FLASHING
Fault with the changegiver
unit.
A coin has covered the
top-level sensor mirrors.
A coin is jammed in the
dispenser module.
Fault with the audit
module.
Coin cassette is
unclipped.
Press A, B, C and D to check if coins are dispensed. If the red LED is still flashing,
switch off the power to the machine, wait at least 15 seconds and switch on
again.Check that coins are dispensed.
Remove the coin cassette and check the tops of the coin tubes.
Switch off the power to the machine, remove the cassette and check the dispenser
for jams.
Clear any blockages and check for damaged coins.
Check the Route Alpha 250 audit addresses.
Return the unit to your MEI distributor for repair if necessary.
Press coin cassette into place firmly, ensure clips snap shut.
Red LED
stays OFF
and all coins
are rejected
No stock available for
vending.
Check for fault on vending
machine.
No blocker signal from the
machine.
LED or keypad fault.
Faulty transformer.
Restock machine if necessary.
If an Executive version machine, check the communications cable. Refer to the
Product Maintenance Handbook.
Check for a full waste bucket. Check if machine is paused halfway through a vend
cycle. Complete the cycle if necessary.
Check the keypad module. If faulty, refer to your MEI distributor.
Check the transformer. If faulty, refer to your MEI distributor.
Problem Causes Actions