Operation Manual

16
GB
8.4 Weekly cleaning
The instant beverage tanks , must be
emptied at least 1x per week and cleaned
with a dry dust brush. Remove any parts
stuck to the tanks.
8.5 Monthly cleaning
Pull out the small drawer behind the air slit
of the funnel and clean.
Empty the instant beverage tanks , at
least 1x per month. Clean with hot water
and a detergent suitable for milk products.
You can also use the combined cleaning
tablets, Order No. 2900018. Dissolve 2
tablets / 1 litre water.
Rinse with clean water.
The feed screw can be dismounted if requi-
red. Loosen screw on the drive side and pull
out the feed screw.
Important! All parts must be dried thoroug-
hly before reassembling.
9. Switching machine off
The machine should be switched off over
night.
Before switching off, a cleaning process
must be carried out (see 8. „Cleaning and
Care“, page 11).