User manual

V5095-581-04 04/13
Mounting bracket (Art. no. 56529.)
Remote control for radio ARGUS 220 CONNECT
(Art. no. 509590)
¼
DANGER
Risk of serious damage to property and per-
sonal injury, e.g. from fire or electric shock,
due to incorrect electrical installation.
Safe electrical installation can only be ensured if
the person in question can prove basic knowl-
edge in the following areas:
Connecting to installation networks
Connecting several electrical devices
Laying electric cables
Outdoor electrical installation
These skills and experience are normally only
possessed by skilled professionals who are
trained in the field of electrical installation technol-
ogy. If these minimum requirements are not met
or are disregarded in any way, you will be solely li-
able for any damage to property or personal inju-
ry.
The radio ARGUS 220 CONNECT (referred to below as
the ARGUS) is a movement detector for indoor and out-
door installation.
Functions:
220° surface monitoring for large house fronts and
sections of the house (max. range. 16 m)
360° short-range zone (approx. 4 m radius)
LED function display for fast alignment at the installa-
tion site.
Operating elements are protected under the easily ac-
cessible cover plate.
Can be installed on walls and ceilings without addi-
tional accessories.
Horizontally, vertically and axially adjustable sensor
head for optimum adaptation to immediate surround-
ings
Hide unwanted zones or sources of disturbance (e.g.
trees) using the segments supplied.
Remote control for setting and operating the ARGUS
conveniently.
Radio ARGUS 220 CONNECT
Operating instructions
Art. no. 5095..
Accessories
For your safety
ARGUS introduction
ende
|
Movement/presence detectors are not suitable
for use as components of an alarm system.
|
Movement/presence detectors can trigger false
alarms if the installation site has been chosen un-
favourably.
Movement/presence detectors switch on as soon as
they detect a moving heat source. This can be a person,
but also animals, trees, cars or differences in tempera-
ture in windows. In order to avoid false alarms, the cho-
sen installation site should be such that undesired heat
sources cannot be detected (see section „Selecting the
installation site“).
The ARGUS operating elements are protected under the
cover plate. The arrow's position on the controllers
shows you the set values.
Using ARGUS with alarm systems
Connections, displays and operating
elements
A Wall connection box
B Top sect ion
C Cover plate
D Sensor head
E Contact pins
F Cable routing for connecting cable from under-
neath
G Cable routing for connecting cable from behind
H Terminal block for the connecting cable and for
locating the contact pins
A ARGUS settings controller
A = Operating mode
B = Learning mode (also for PC-Tool)
C = Reset
D = Adopt potentiometer settings
B Switching duration controller
C Brightness threshold controller
D Functional display (lights up each time move-
ment is detected)
E Brightness sensor (must not be covered)
F Sensitivity controller
A
B
C
D
E
H
G
F
A
E
B
C
D
F
A
C
BD
Explanation of the symbols used
When selecting a suitable installation site, you should
take a number of factors into account so that the move-
ment detector operates optimally.
|
The following figure shows the ranges of the AR-
GUS at average temperature conditions and a
mounting height of 2.5 m. The range of a move-
ment detector can vary greatly depending on the
temperature.
Inner security zone A: Angle of detection 360° over
a radius of approx. 4 m.
Middle security zone B: Angle of detection 220°
with an area of detection of approx. 9 m x 18 m.
Outer security zone C: Angle of detection 220° with
an area of detection of approx. 16 m x 28 m.
Mounting height D: 2-3 m. For optimum monitoring,
we recommend a height of 2.5 m on a solid and even
base.
Minimum distance E to sources of optical interfer-
ence: 5 m If necessary, use the segments supplied to
shade the device.
Minimum distance F between luminaire and move-
ment detector: 5 m. If this distance cannot be
achieved, you can use the segments provided to
"mask" the light source from the area of detection.
Selecting the installation site
Correct
Not optimal
Incorrect
0
2
4
6
8
10
2
4
6
8
10
12
12
14
14
0
4 2 4 6 8 10 12 14 16 m
B
0
0 2 4 6 8 10 12 14 16 m
2,5
m
4
0,8 m
2
C
A
D
E
E
OK
OK
F
If possible, install the movement detector sideways to the
direction of movement.
To avoid the connected load being switched on due to
environmental influences, the ARGUS should be in-
stalled so that it is protected against rain and direct sun-
light. A raindrop running over the lens, for example, can
activate the movement detector.
If you wish to attach several movement detectors, install
them so that the detection areas of the individual move-
ment detectors intersect each other.
OK
OK
OK
Dismantlement of the top section of the ARGUS
Installing the ARGUS to the wall
Feeding in the connecting cable
ARGUS installation
1
2
3
1
2
1
2
=
=
Installing the ARGUS on the ceiling
In order to install the ARGUS on the ceiling, you must ro-
tate the sensor head. Change the direction of rotation
once you have reached the end stops.
1 Turn the sensor head upwards as far as it will go.
2 Turn the sensor head clockwise as far as it will go.
3 Align the sensor head.
½
CAUTION
If not installed correctly, the device can be
damaged by condensation.
In the case of sloping ceilings, install the device
so that spherical head is pointing down and al-
ways at an angle of 15° - 90°. When the spherical
head points downwards, any water from conden-
sation could run down the device.
|
Type of protection IP 55 cannot be guaranteed if
the mounting bracket is not 15° - 90°.
Installing the ARGUS on corners and fixed pipes
You can attach the ARGUS to inner/outer corners or fixed
pipes using the mounting bracket (art. no. 56529x). You
can feed the connecting cable to the device from behind
through the mounting bracket.
1
2
3
15° - 90°