User manual

V5095-581-04 04/13
½
CAUTION
The device can become damaged.
Operation only possible with sinusoidal mains
voltages. Phase control dimmers or inverters with
square-wave or trapezoidal voltage curves will
damage the device.
|
Protect the ARGUS using a 16 A circuit breaker.
|
When switching inductive loads such as trans-
formers, relays, contactors or fluorescent lamps,
spikes occur which could lead to the load being
switched on again ("maintained light effect").
Connect a capacitor in parallel to the inductive
load to reduce these spikes.
"Through-wiring" to other loads is permitted.
ARGUS permanently connected to the mains
The ARGUS constantly monitors its area
Installation of the top section of the ARGUS
The ARGUS can now be put into operation.
1 Connect the supply voltage.
The load is switched on for approx. 10 s or for the set pe-
riod. The functional display lights up for approx. 10 s.
2 Teach the remote control.
Connecting the ARGUS
Putting ARGUS into operation
14 mm
L
N
LN
1
2
3
Conducting a functional test
|
The brightness sensor must not be covered up.
|
The functional display lights up each time move-
ment is detected.
½
CAUTION
The device could become damaged.
The sensor head should only be rotated until it
reaches the stop and no further. To achieve an
angle "above" the stop, change the direction of
rotation.
1 Align the sensor head in the direction of the area
that is to be monitored.
2 From its edge step into the area of detection to see
whether the ARGUS switches the load and the func-
tional display as required.
Setting the sensitivity
Here you can infinitely set the distance up to which AR-
GUS detects movements (any distance up to max. 16
m).
Setting up the ARGUS manually
A
C
BD
12
3
4
1s
5
=
24°
12°12°
12° 12°
29°
8,5°
8,5°
25°
25°
Setting the brightness threshold
Here you can infinitely set the ambient brightness level at
which the ARGUS detects movements and triggers a
switching procedure.
Moon symbol (night operation): The ARGUS will only
detect movements during the hours of darkness (ap-
prox. 3 lux).
Sun symbol (day and night operation): The ARGUS
detects movements up to approx. 1000 lux.
Setting the switching duration
Here you can set how long the loads connected to AR-
GUS are switched on for. When a movement is detected,
the load is switched on and stays switched on until the
set period has elapsed. Every further movement restarts
the switching duration.
|
The ARGUS ignores the light-sensitive switch
once the load has been switched on. If the move-
ment detector does not switch the load off again,
the reason probably is that the ARGUS constantly
detects further movements and thus keeps re-
starting the switching duration.
Blocking out individual areas
Using the four segments supplied, you can block out un-
wanted zones and sources of interference from the area
of detection.
|
Ensure that the brightness sensor A is not cov-
ered, as the sensitivity to light is otherwise re-
duced.
Turn the controller A on the ARGUS back to positioin
A: The ARGUS is ready to use.
Reset to the factory settings
Under certain circumstances, it may be neccessary to
reset this device to its factory settings and to reconfigure
it:
½
CAUTION
Malfunctions can occur!
When resetting to the factory settings, all the set-
tings and connections for this CONNECT device
are deleted. Maybe the radio system is not work-
ing any longer and must be reconfigured (See the
separate description of the CONNECT radio sys-
tem).
1 Turn the controller A on the ARGUS to position C.
2 After approx. 1 s the LED flashes short: The device
has now been reset to its factory settings.
Resetting the ARGUS
3 LUX 1000 LUX
1s
40
80
20
3
8
min
1,2 sec
1s
40
80
20
3
8
min
8 min 10 sec
A
12
As a component of the radio system CONNECT you can
connect the ARGUS with 5 additional CONNECT devic-
es.
|
If you want to connect the ARGUS with other
CONNECT devices (exepted the radio ARGUS
220 CONNECT), you should do this connection
via the CONNECT radio USB data interface (with
a corresponding PC) and the CONNECT radio
configurator.
1 Turn the controller A on the ARGUS to position B:
The learning mode is activated.
|
You can analyse and check faults throughout the
radio system with the help of the CONNECT radio
USB data interface (on a suitable PC) and the
CONNECT radio configuration tool.
The device is not reacting to the transmitter
Make sure that the maximum range is not exceeded
and that there are no metal surfaces such as metal
cabinets in the radio transmission path.
If necessary, check that the device is connected cor-
rectly to the supply voltage.
Make sure that the device is not in programming
mode. (If the LED is constantly flashing or constantly
lit up, this is the case).
If necessary, repeat the programming process again.
Radio ARGUS in the CONNECT radio
system
What should I do if there is a problem?
Te c h n i c a l d a ta
ARGUS
Nominal voltage: AC 230 V ±10%, 50 Hz
Fuse: Protect the ARGUS using a 16 A
circuit breaker.
Max. switching
current: 16 A, AC 230 V, cosϕ = 1
Nominal output
Incandescent
lamps: AC 230 V, max. 2000 W
Halogen lamps: AC 230 V, max. 1200 W
Fluorescent lamps: AC 230 V, max. 1200 W,
uncompensated
Capacitive load: 35 µF
Transformer load: max. 600 VA
Power consumption: < 1 W
Connecting terminals: for 2x1.5 mm
2
or 2x2.5 mm
2
rig-
id conductor, stripped length
14 mm
External diameter of
one cable: max. 14.5 mm
Angle of detection: 220°
Range: max. 16 m
Number of levels: 7
Number of zones: 112 with 448 switching seg-
ments
Minimum mounting
height: 1.7 m
Recommended
mounting height: 2.5 m
Sensitivity: infinitely adjustable
Light sensor: infinitely adjustable externally,
from appr. 3 lx to appr. 1000 lx
Switching duration: externally adjustable in 6 levels
of approx. 1 s to appr. 8 min
Possible settings for
sensor head
Wall mounting: 9° up, 24° down, 12° left/right,
± 12° axial
Ceiling mounting: 4° up, 29° down, 25° left/right,
± 8.5° axial
Type of protection: IP 55 at an angle of inclination
from 15° to 90°
EC directives: Low-voltage guideline
2006/95/EC
EMC directive 2004/108/EC
Information for experienced users who want to use this
device with Z-wave compatible devices from other man-
ufacturers:
|
This device can be used with other Z-wave com-
patible devices; also with devices from other
manufacturers. Each Z-wave compatible device
can be added to a Z-wave system and also works
as a router unless the routing of orders is support-
ed. The configuration of a CONNECT radio sys-
tem is described in the separate "CONNECT
radio system" description. Some programming is
only possible with devices that are compatible
with the CONNECT radio system.
Merten GmbH, Fritz-Kotz-Str. 8, D-51674 Wiehl
www.merten.com
Service Center:
Technical support/InfoLine:
Z-wave device type Enhanced Slave
Learn-Mode:
(for integration into
Z-wave systems of
other manufacturers)
Turn the controller A on the AR-
GUS to position B. LED flashes
for a period of approx. 6 s
Transmit „Node Info
Frame“: Turn the controller A on the AR-
GUS to position B
List of functions Parameter number
Power-on time 181, 182
Association Group Verwendung
1 Master (Output Light Control)
2 Report (Output „Status Report“)
Z-wave designation CONNECT designation
Inclusion Program (transmits Node Info
Frame), see the separate de-
scription of the CONNECT radio
system
Exclusion Reset to the factory settings;
complete programming
Primary Device with system administra-
ton
Merten GmbH
Phone: +49 2261 702-204
Fax: +49 2261 702-136
E-Mail: servicecenter@merten.de
Phone: +49 2261 702-235
Fax: +49 2261 702-680
E-Mail: infoline.merten@schneider-electric.com