User manual

V5655-581-02 04/13
Installing the ARGUS on corners and fixedpipes
You can attach the ARGUS to inner/outer corners or fixed
pipes using the mounting bracket (art. no. 5652..). You
can feed the connecting cable to the device from behind
through the mounting bracket.
½
CAUTION
The device can become damaged.
Operation only possible with sinusoidal mains
voltages. Phase control dimmers or inverters with
square-wave or trapezoidal voltage curves will
damage the device.
|
Protect the ARGUS using a 16 A circuit breaker.
|
When switching inductive loads such as trans-
formers, relays, contactors or fluorescent lamps,
spikes occur which could lead to the load being
switched on again ("maintained light effect").
Connect a capacitor in parallel to the inductive
load to reduce these spikes.
"Through-wiring" to other loads is permitted.
ARGUS permanently connected to the mains
The ARGUS constantly monitors its area
Installation of the top section of the ARGUS
The ARGUS can now be put into operation.
Connecting the ARGUS
14 mm
L
N
LN
1
2
3
1 Connect the supply voltage.
The load is switched on for approx. 10 s or for the set pe-
riod. The functional display lights up for approx. 10 s.
2 Teach the remote control.
Conducting a functional test
|
The brightness sensor must not be covered up.
|
The functional display lights up each time move-
ment is detected.
½
CAUTION
The device could become damaged.
The sensor head should only be rotated until it
reaches the stop and no further. To achieve an
angle "above" the stop, change the direction of
rotation.
1 Align the sensor head in the direction of the area
that is to be monitored.
2 From its edge step into the area of detection to see
whether the ARGUS switches the load and the func-
tional display as required.
Setting the sensitivity
Here you can infinitely set the distance up to which AR-
GUS detects movements (any distance up to max. 16
m).
Putting ARGUS into operation
Setting up the ARGUS manually
A
C
BD
12
3
4
1s
5
=
24°
12°12°
12° 12°
29°
8,5°
8,5°
25°
25°
Setting the brightness threshold
Here you can infinitely set the ambient brightness level at
which the ARGUS detects movements and triggers a
switching procedure.
Moon symbol (night operation): The ARGUS will only
detect movements during the hours of darkness (ap-
prox. 3 lux).
Sun symbol (day and night operation): The ARGUS
detects movements up to approx. 1000 lux.
Setting the switching duration
Here you can set how long the loads connected to AR-
GUS are switched on for. When a movement is detected,
the load is switched on and stays switched on until the
set period has elapsed. Every further movement restarts
the switching duration.
|
The ARGUS ignores the light-sensitive switch
once the load has been switched on. If the move-
ment detector does not switch the load off again,
the reason probably is that the ARGUS constantly
detects further movements and thus keeps re-
starting the switching duration.
Blocking out individual areas
Using the four segments supplied, you can block out un-
wanted zones and sources of interference from the area
of detection.
|
Ensure that the brightness sensor A is not cov-
ered, as the sensitivity to light is otherwise re-
duced.
Reset to the factory settings
Under certain circumstances, it may be neccessary to
reset this device to its factory settings and to reconfigure
it:
½
CAUTION Malfunctions can occur! When re-
setting to the factory settings, all the settings and
connections for this CONNECT device are delet-
ed. Maybe the radio system is not working any
longer and must be reconfigured (See the sepa-
rate description of the CONNECT radio system).
1 Turn the controller A on the ARGUS to position C.
2 After approx. 1 s the LED flashes short: The device
has now been reset to its factory settings.
Resetting the ARGUS
3 LUX 1000 LUX
1s
40
80
20
3
8
min
1,2 sec
1s
40
80
20
3
8
min
8 min 10 sec
A
12
Resetting to the factory settings
Under certain circumstances, it may be neccessary to
reset this device to its factory settings and to reconfigure
it:
½
CAUTION
When you reset to the factory settings, all the set-
tings and connections for this device are deleted.
1 Turn the controller A on the ARGUS to position C.
2 Wait until the red LED on the ARGUS goes out
(approx. 5 s): The device has now been reset to its
factory settings.
|
Only 1 ARGUS can be taught per remote control!
Activating the remote control
1 Remove the protective foil: The remote control is
ready to use immediately!
Teaching the ARGUS for use with remote control
|
You can use the remote control to adjust the AR-
GUS simply and conveniently during operation.
Setting up the ARGUS via remote
control
A Setting: ARGUS operating mode
B Setting: Brightness
C Setting: Overshoot time
D Setting: Sensitivity
E Status LED (red, green)
AUTO ON OFF
SET
-30s
+30s
SET
+
merten
A
B
C
D
1
2
=
AUTO
A
C
D
3x
„B“
10 s
3
4
C
D
„A“
B
AUTO ON OFF
SET
-30s
+30s
SET
+
merten
AUTO ON OFF
SET
-30s
+30s
SET
+
merten
6s
15 s
Setting the operating mode
Use the buttons to select one of the following statuses:
–Press the [ON] button: The local ARGUS is perma-
nently active, regardless of whether or not movement
is detected (permanent ON).
–Press the [OFF] button: The local ARGUS is perma-
nently switched off (permanent OFF).
–Press the [AUTO] button: .f the ARGUS is already on,
the overshoot time is started (automatic mode). Other-
wise the ARGUS remains off until a movement is de-
tected.
Setting the brightness threshold
–Press the [SET] button: the current brightness value is
adopted.
Setting the switching duration
–Press the [+30] or the [-30] button: the current over-
shoot time is reduced or increased by 30 s per push
of the button.
Setting the sensitivity
–Press the [SET] button: ARGUS flashes fast: Teach-
ing mode activated (controller F at the ARGUSat max-
imum). Then, run across the sensor range of the
ARGUS once within 30 s. The sensitivity of the AR-
GUS is set such that the measured movement is de-
tected. You can alter this value afterwards using the [+]
and [-] buttons.
|
Always insert the battery with the (+) pole facing
upwards.
1 Press the [AUTO] button 3 times and hold it down
until the green light goes out. The remote control
has been cleared.
Status LED
Red light Remote control no longer connected to
ARGUS
Flashing red
light
Teaching mode activated
Green light Remote control connected to ARGUS
How to change the battery
Reset remote control
2
3
1
Gothaer Straße 29, 40880 Ratingen
www.merten.com
www.merten-austria.at
Customer care centre:
Technical data
Remote control
Channels: 1
Radio frequency: 868 mHz
Range Free field: up to 100 m
Indoors: up to 30 m
Battery: 1 lithium button cell (CR 2450N)
Display elements: Status-LED
ARGUS
Nominal voltage: AC 230 V ±10%, 50 Hz
Fuse: Protect the ARGUS using a 16 A
circuit breaker.
Max. switching cur-
rent:
16 A, AC 230 V, cosϕ = 1
Nominal output
Incandescent
lamps:
AC 230 V, max. 2000 W
Halogen lamps: AC 230 V, max. 1200 W
Fluorescent lamps: AC 230 V, max. 1200 W,
uncompensated
Capacitive load: 35 µF
Transformer load: max. 600 VA
Power consumption: < 1 W
Connecting terminals: for 2x1.5 mm
2
or 2x2.5 mm
2
rig-
id conductor, stripped length
14 mm
External diameter of
one cable:
max. 14.5
mm
Angle of detection: 220°
Range: max. 16 m
Number of levels: 7
Number of zones: 112 with 448 switching seg-
ments
Minimum mounting
height:
1.7 m
Recommended
mounting height:
2.5
m
Sensitivity: infinitely adjustable
Light sensor: infinitely adjustable externally,
from approx. 3 lux to approx.
1000 lux
Switching duration: externally adjustable in 6 levels
of approx. 1 sec. to approx.
8min.
Possible settings for
sensor head:
Wall mounting: 9° up, 24° down, 12° left/right, ±
12° axial
Ceiling mounting: 4° up, 29° down, 25° left/right, ±
8.5° axial
Type of protection: IP 55 at an angle of inclination
from 15° to 90°
EC directives: Low-voltage guideline
2006/95/EC
EMC directive 2004/108/EC