Instruction Manual

12
Use a shielded wire for the wind sensor connection (we
suggest: JY-ST-Y 2x2x0.6). Do not lay the cable together
with 230 V wires (risk of interference).
The wind sensor is connected to the blind control insert
using the wind sensor interface.
1. Remove the lid of the connection housing (Figure
!1) by removing the two screws (Figure !2). (If
the cable entry is at the back, pierce through the
rubber grommet (Figure „2) and insert the wire).
2. Secure the device using two screws.
3. Insert cables into the connection housing and
connect them as shown in Figure §.
The wind sensor interface is equipped with floating
make contacts. For use at the same phase, install a
bridge between L and K as per Figure §. When low-
Connecting the wind sensor interface