Specification
LCRL
PS502105EN page 2
February 3, 2020 1:33 PM
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
© 2020 Cooper Lighting Solutions
All Rights Reserved.
Specifications and dimensions
subject to change without notice.
Product Specications
Construction
• Die formed code gauge steel with full length die-
formed stiffeners
• Unibody endplates attached with interlocking tabs
and screws
• Hemmed side anges and four auxiliary xture end
suspension points
• Recessed lay-in installation. Fits standard T-grid
systems
• Integral Grid-lock endplates mean an added safety
feature
Electrical
• 120-277V electronic driver, Class A
• Standard 0-10V dimming to 10%
• 0-10V dimming uses low-voltage grey and purple
wire leads
Shielding
• Ribbed acrylic frosted lens provides general area
coverage and light distribution (8’x10’)
LED and Light Engine
• 4000K CCT and minimum 80 CRI
• L94 at 60,000 rated life-hours (TM-21), or up to 27
years at 6 hrs/day.
• LED modules comply with IESNA LM-79 and LM-80
standards
Finish
• Matte white polyester powder coat nish
Compliance and Certifications
• cULus listed for damp location in 25°C ambient
environments
• DesignLights Consortium Qualied, refer to www.
designlights.org for details
Product Warranty
• 5-year warranty
Accessories
• CZ2-EQCLIP-U-PK = T-BAR Safety Earthquake Clips
(4 clips per bag) - Recommended for all 9/16” T-grid
ceilings)
• DF-22W-U = 2’ x 2’ Drywall Frame Kit
• SK-22-WS = 2’ x 2’ Shallow Surface Mount Kit
• DF-24W-U = 2’ x 4’ Drywall Frame Kit
• SK-24-WS = 2’ x 4’ Shallow Surface Mount Kit
Product Information
Ceiling Trim
Type Type
Exposed Grid Standard
Concealed TStandard
Slot Grid Standard
Flange *
G
Grid/Lay-in
Standard
G
Concealed T
G
Slot Grid
*See Drywall Frame Kit
Accessory
in Ordering Information Section
Ceiling Compatibility
Catalog Number Lumen Wattage UPC Unit Weight Pallet Quantity
22LCRL3040C 3,273 23 080083889877 12.5 lbs 48
24LCRL4040C 4,208 34.7 080083889884 27.1 lbs 26