Checking the Hydraulic Brake Fluid Levels
To check the brake fluid level remove the reservoir cap located on the right hand side of the
dash.
How to add brake fluid:
1. Open the cap of the oil reservoir and take out the oil seal.
2. Add the brake fluid to the position 5mm below the top of the reservoir.
3. Put the oil seal in the reservoir and tighten the cap of the reservoir.
When adding the brake fluid, do not spill the fluid on the cart especially the surface with
paint this can cause damage.
Never operate your cart if the brake pedal does not feel firm.
Immediately stop operation if your cart pulls severely to one side while braking. Do not
continue operation.
Your cart is equipped with all round wheel Brakes, designed to limit your speed.
The main pedal braking is done on all four wheels with a hydraulic brake system which
includes front wheel disc brakes and rear wheel drum brakes. This system requires
periodic inspection for brake pad wear, drum / rotor wear and hydraulic fluid loss.
Consult your a qualified Technician if excess wear or if fluid loss is noted. Do not attempt
to move the cart if any of these conditions are present.
The second braking system is a hand operated parking brake. This hand lever technically
engages the rear brakes to keep the car stationary when parked or left unattended.
Always engage the parking brake when parking the cart or before leaving it unattended.
Battery Pack Maintenance:
While charging, batteries emit hydrogen which is an explosive gas. Keep the cart in well
ventilated areas while charging.
Do not smoke or expose sparks or open flames near the cart.
The electrolyte in the batteries is highly acidic and poisonous. Avoid contact with skin,
eyes, and clothing. Severe burning and scaring may result.
Remedial measures in case of contact with battery acid:
- External: Flush with water for 15 minutes. Call physician immediately.
- Internal: Drink large quantities of milk or water followed with milk of magnesia or
vegetable oil. Call physician immediately.
- Eyes: Flush with water for 15 minutes. Call physician immediately.
CAUTION
DANGER
DANGER