Instruction manual

99
4
PARAMETERS
REMARKS
This function is invalid during jog operation and PID control operation.
Even when the remotely-set frequency is cleared by turning on the RL (clear)
signal after turn off (on) of both the RH and RM signals, the inverter operates at
the remotely-set frequency stored in the last operation if power is reapplied
before one minute has elapsed since turn off (on) of both the RH and RM signals
When the remotely-set frequency is cleared by turning on the RL (clear) signal
after turn off (on) of both the RH and RM signals, the inverter operates at the
frequency in the remotely-set frequency cleared state if power is reapplied after
one minute has elapsed since turn off (on) of both the RH and RM signals.
CAUTION
When selecting this function, re-set the maximum frequency according to
the machine.
Setting frequency is "0"
Clear (RL)
Acceleration (RH)
Forward rotation (STF)
Output
frequency
(Hz)
ON
Power supply
ON
ON
ON
ON
ON
Within one minute
Remotely -set frequency
stored in the last operation
Deceleration (RM)
OFF
Remotely -set frequency
stored in the last operation
Operation at a set
frequency of 0Hz
ON
ON
ON
ON
ON
ON
1 minute
OFF
Clear (RL)
Acceleration (RH)
Forward rotation (STF)
Output
frequency
(Hz)
Power supply
More than
one minute
Remotely -set frequency
stored in the last operation
Deceleration (RM)