Instruction manual

160
PARAMETERS
When not adjusting the gain voltage go to (5)-1)
When adjusting any point by applying a voltage go to (5)-2)
When adjusting any point without applying a voltage go to (5)-3)
(5)-1)How to adjust only the gain frequency and not to adjust the voltage
(5)-2) How to adjust any point by applying a voltage across terminals 2-5 (e.g. from the
external potentiometer) (current: across terminals 4-5) (when applying 5V))
(5)-3)How to adjust any point without applying a voltage across terminals 2-5 (without a
current flowing across terminals 4-5) (when changing from 4V (80%) to 5V (100%)
Press for 1.5s
SET
PU
EXT
MON
Hz
RUN
A
Flicker
Analog voltage value (%)
across terminals 2-5
Press the or key once to display
the current analog voltage calibration value.
Example: When analog voltage
adjustment value is
100% (5V)
go to (6)
Press for 1.5s
PU EXT
MON
Hz RUN
A
Flicker
Analog voltage
value (%) across
terminals 2-5
Apply a 5V voltage.
(Turn the external potentiometer
connected across terminals 2-5 to maximum.)
SET
When the potentiometer
is at the maximum position,
the value is nearly 100 (%).
go to (6)
Press for 1.5s
PU
EXT
MON
Hz
RUN
A
Flicker
Analog voltage
value (%) across
terminals 2-5
SET
Set the gain voltage (%)
with the key.
[0(%) for 0V (0mA), 100(%)
for 5V (10V, 20mA)]
/
/
Press the or key
once to display the current
analog voltage calibration
value.
go to (6)
M4500E.book 160 ページ 2005年2月22日 火曜日 午後5時7分