Instruction manual

184
MAINTENANCE/INSPECTION
Removal
1) Remove the front cover (Refer
to page 6).
2) Unplug the fan connector.
The cooling fan is connected to
the cooling fan connector
beside the main circuit terminal
block of the inverter.
Unplug the connector.
3) Remove the inverter and
cooling fan.
Push in the direction of arrow A
and pull out in the direction of
arrow B.
4) Remove the cooling fan and
cooing fan cover.
The cooling fan is secured by
the fixing hooks.
You can remove the cooling
fan and cooling fan cover by
disengaging the fixing hooks.
Fan connector
A
A
B
Cooling fan cover
Cooling fan
M4500E.book 184 ページ 2005年2月22日 火曜日 午後5時7分