Instruction manual

26
INSTALLATION AND WIRING
2) Sink logic type
In this logic, a signal switches on when a current flows out of the corresponding signal
input terminal.
Terminal SD is common to the contact input signals. Terminal SE is common to the
open collector output signals.
Use terminal PC as a common terminal to prevent a malfunction caused by
undesirable current.
(Do not connect terminal SD of the inverter with terminal 0V of the external power
supply. When using terminals PC-SD as a 24VDC power supply, do not install the
power supply in parallel outside the inverter. Doing so may cause misoperation due to
undesirable current.)
Current
STF
STR
R
R
SD
AX40Inverter
R
R
RUN
SE
1
9
24VDC
9
10
24VDC
SD
PC
24VDC
(SD)
AY40 type
transistor output
module
Inverter
1
2
STR
STF
Current flow
M4500E.book 26 ページ 2005年2月22日 火曜日 午後5時7分