Instruction manual

29
2
INSTALLATION AND WIRING
<System configuration example>
(1) Connection of a computer to the inverter (1:1 connection)
Computer-inverter connection cable
For a connection cable between the computer having RS-232C and the inverter (RS-
232CRS-485 converter), refer to the table below.
Example of product available on the market (as of April, 2004)
* The converter cable cannot connect two or more inverters (the computer and
inverter are connected on a 1:1 basis). Since the product is packed with the RS-
232C cable and RS-485 cable (10BASE-T + RJ-45 connector), the cable and
connector need not be prepared separately. Contact a maker for details of the
product.
Model Maker
FA-T-RS40* Mitsubishi Electric Engineering Co., Ltd.
REMARKS
Refer to the following when fabricating the cable on the user side.
Example of product available on the market (as of April, 2004)
RS-485
connector
Inverter
Station 0
Computer
RS-485
interface/
terminal
10BASE-T cable 1)
RJ-45 connector 2)
RS-485
connector
Inverter
Station 0
Computer
10BASE-T cable 1)
RJ-45 connector 2)
RS-232C
cable
RS-232C
connector
RS-232C RS-485
converter
Max. 15m
(49.21 feet)
Product Model Maker
1) 10BASE-T cable
SGLPEV-T 0.5mm × 4P
* Do not use No. 2 and No. 8
pin (P5S).
Mitsubishi Cable Industries, Ltd.
2) RJ-45 connector 5-554720-3 Tyco Electronics Corporation
M4500E.book 29 ページ 2005年2月22日 火曜日 午後5時7分