Instruction manual

52
OPERATION/CONTROL
(1) Example:To change the Pr. 79 "operation mode selection" setting
from "2" (external operation mode) to "1" (PU operation mode)
(For details of Pr. 79, refer to page 111.)
SET
Current setting
Setting change
Press for
1.5s
SET
Middle digit flickers
Most significant
digit flickers
SET
Least significant
digit flickers
0 to 9
PU
MODE SET REV
STOP
RESET
FWD
SET
Parameter setting mode
Setting write
Flicker
MODE
To 3.2.6 Operation mode
0 to 9
Press the key, to choose the
parameter setting mode.
MODE
When appears
1) If the RUN indication is lit or flickering,
stop operation by pressing the
key or turning off the forward rotation
(STF) or reverse rotation (STR) signal
connected to the control terminal.
2) You cannot set any value that is outside the
parameter setting range. Write a value within
the setting range.
RUN
STOP
RESET
SET
× 7 times
or
× 3 times
× 9 times
or
× 1 time
"1" (PU operation mode) has been set in Pr. 79.
If the value and do not flicker but
appears, you did not press the key
for 1.5s when writing the value.
Press the key once, press the key, and
restart the setting from the beginning.
SET
SET
M4500E.book 52 ページ 2005年2月22日 火曜日 午後5時7分