PARAMETERS
4.2.10 Jog operation (Pr. 15, Pr. 16)
Pr. 15 "jog frequency"
Pr. 16 "jog acceleration/
deceleration time"
Jog operation can be started and stopped by selecting the jog mode from the operation
panel and pressing and releasing the key ( , key).
Set the frequency and acceleration/deceleration time for jog operation.
Parameter
Number
Factory
Setting
Setting
Range
Remarks
15 5Hz 0 to 400Hz
16 0.5s
0 to 3600 s When Pr. 21 = 0
0 to 360 s When Pr. 21 = 1
Note:1. In S-shaped acceleration/deceleration pattern A, the acceleration/
deceleration time is the period of time required to reach Pr. 3 "base
frequency", not Pr. 20.
2. The acceleration time and deceleration time cannot be set separately for jog
operation.
3. The value set in Pr. 15 "jog frequency" should be equal to or greater than
the Pr. 13 "starting frequency" setting.
4. When Pr. 79 Operation mode selection="4", pressing / of the PU
(FR-PA02
-02, FR-PU04-MGI) starts the inverter and pressing stops
the inverter.
Pr. 18 Refer to Pr. 1, Pr. 2.
Pr. 19 Refer to Pr. 3.
Pr. 20, Pr. 21 Refer to Pr. 7, Pr. 8.
Pr. 20 "acceleration/deceleration
reference frequency"
Pr. 21 "acceleration/deceleration
time increments"
Related parameters
RUN
FWD
REV
Pr.15
Time
Pr.20
Pr.16
Output frequency (Hz)
Jog frequency
setting range
ON
ON
Forward
rotation
Reverse
rotation
REV
key
FWD
key
FWD
REV
STOP
RESET
M4500E.book 81 ページ 2005年2月22日 火曜日 午後5時7分