PARAMETERS
136
Pr. 52 "DU/PU main display data
selection"
Related parameter
z
zz
z Watt-hour meter clear/actual operation hour meter clear (Pr. 170, Pr. 171)
Pr. 170 "watt-hour meter clear"
Pr. 171 "actual operation hour meter clear"
You can clear the watt-hour value and actual operation hour monitoring function.
Parameter
Number
Factory
Setting
Setting Range
170 0 0
171 0 0
<Setting>
Write "0" in the parameters to clear the watt-hour value and actual operation hour.
Pr. 173 to Pr. 176
Î
ÎÎ
Î
Refer to Pr. 160.
z
zz
z Input terminal function selection (Pr. 180 to Pr. 186)
Pr. 180 "RL terminal function selection"
Pr. 181 "RM terminal function selection"
Pr. 182 "RH terminal function selection"
Pr. 183 "RT terminal function selection"
Pr. 184 "AU terminal function selection"
Pr. 185 "JOG terminal function selection"
Pr. 186 "CS terminal function selection"
Use these parameters to select/change the input terminal functions.
Parameter
Number
Terminal
Symbol
Factory
Setting
Factory-Set Terminal Function Setting Range
180 RL 0 Low-speed operation command (RL) 0 to 20, 22, 23, 9999
181 RM 1 Middle-speed operation command (RM) 0 to 20, 22, 23, 9999
182 RH 2 High-speed operation command (RH) 0 to 20, 22, 23, 9999
183 RT 3 Second function selection (RT) 0 to 20, 22, 23, 9999
184 AU 4 Current input selection (AU) 0 to 20, 22, 23, 9999
185 JOG 5 Jog operation selection (JOG) 0 to 20, 22, 23, 9999
186 CS 6
Automatic restart after instantaneous
power failure selection (CS)
0 to 20, 22, 23, 9999