PARAMETERS
137
<Setting>
Refer to the following list and set the parameters:
Setting
Signal
Name
Functions Relevant Parameters
Pr. 59 = 0
Low-speed operation command
Pr. 4 to Pr. 6
Pr. 24 to Pr. 27
Pr. 232 to Pr. 239
Pr. 59 = 1, 2 * Remote setting (setting clear)
Pr. 59
Pr. 79 = 5 *
Programmed operation group
selection
Pr. 79, Pr. 200, Pr. 201 to Pr. 210, Pr. 211
to Pr. 220, Pr. 221 to Pr. 230, Pr. 231
0RL
Pr. 270 = 1, 3 * Stop-on-contact selection 0
Pr. 270, Pr. 275, Pr. 276
Pr. 59 = 0
Middle-speed operation
command
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to
Pr. 239
Pr. 59 = 1, 2 * Remote setting (deceleration)
Pr. 59
1RM
Pr. 79 = 5 *
Programmed operation group
selection
Pr. 79, Pr. 200, Pr. 201 to Pr. 210, Pr. 211
to Pr. 220, Pr. 221 to Pr. 230, Pr. 231
Pr. 59 = 0
High-speed operation command
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Pr. 59 = 1, 2 * Remote setting (acceleration)
Pr. 59
2RH
Pr. 79 = 5 *
Programmed operation group
selection
Pr. 79, Pr. 200, Pr. 201 to Pr. 210, Pr. 211
to Pr. 220, Pr. 221 to Pr. 230, Pr. 231
Second function selection
Pr. 44 to Pr. 50
3RT
Pr.270 = 1, 3 * Stop-on-contact selection 1
Pr. 270, Pr. 275, Pr. 276
4 AU Current input selection
Refer to page 11
5 JOG Jog operation selection
Pr. 15, Pr. 16
6CS
Automatic restart after instantaneous power failure
selection
Pr. 57, Pr. 58, Pr. 162 to Pr. 165
7OH
External thermal relay input**
The externally provided overheat protection thermal relay,
motor-embedded temperature relay or the like is operated
to stop the inverter.
Refer to page 172
8 REX 15-speed selection (combination with RL, RM, RH)
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
9 X9 Third function
Pr. 110 to Pr. 116
10
11
For manufacturer's.
Do not set.
12 X12 PU operation external interlock
Pr. 79
13 X13 External DC dynamic braking start
Pr. 10 to Pr. 12
14 X14 PID control valid terminal
Pr. 128 to Pr. 134
15 BRI Brake opening completion signal
Pr. 278 to Pr. 285
16 X16 PU-external operation switch-over
Pr. 79
17 X17 Load pattern selection forward/reverse rotation boost
Pr. 14
18 X18 Advanced magnetic flux vector-V/F switch-over
Pr. 80, Pr. 81, Pr. 89
19 X19 Load torque high-speed frequency
Pr. 271 to Pr. 274
20 X20 S-pattern acceleration/deceleration C switch-over terminal
(only when FR-A5AP option is fitted)
Pr. 380 to Pr. 383
22 X22 Orientation command (Note 11) (only when FR-A5AP
option is fitted)
Pr. 350 to Pr. 369
23 LX Pre-excitation (Note 2) (only when FR-A5AP option is fitted)
Pr. 80, Pr.81, Pr. 359, Pr. 369, Pr. 370
9999 No function
*: When Pr. 59 = "1" or "2", Pr. 79 = "5", and Pr. 270 = "1" or "3" the functions of the RL, RM, RH and RT signals change as listed
above.
**: Operated when the relay contact "opens".