OPERATION/CONTROL
46
3.3.3 PU operation mode
(Operation using the operation panel (FR-DU04))
(
1
)
Operation at 60Hz
While the motor is running, repeat the following steps 2 and 3 to vary the speed:
Step Description Image
1
Power-on Operation mode check
Switch power on and make sure that the operation command
indication "PU" is lit.
(If it is not lit, switch to the PU operation mode. For operation mode
changing, refer to page 40.)
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
ON
2
Running frequency setting
Set the running frequency to 60Hz.
First, press the [MODE] key to select the frequency setting mode.
Then, press the [UP/DOWN] key to change the setting, and press
the [SET] key to write the frequency.
(or)
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
3
Start
Press the [FWD] or [REV] key.
The motor starts running. The monitoring mode is automatically
selected and the output frequency is displayed.
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
REVFWD
(or)
4
Stop
Press the [STOP] key.
The motor is decelerated to a stop.
FR-DU04
CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
(
2
)
PU jog operation
Hold down the [FWD] or [REV] key to perform operation, and release it to stop.
1) Set Pr. 15 "jog frequency" and Pr. 16 "jog acceleration/deceleration time".
2) Select the PU jog operation. (Press the [MODE] key to switch to the operation mode and press the
[UP/DOWN] key to choose the PU jog operation.)
3) Hold down the [FWD] or [REV] key to perform operation.
(If the motor remains stopped, check Pr. 13 "starting frequency". The motor will not start if its setting is
lower than the starting frequency.)
3