PARAMETERS
51
Func-
tion
Parameter
Number
Name Setting Range
Minimum
Setting
Increments
Factory Setting
Refer
To
Page:
Customer
setting
148 Stall prevention level at 0V input 0 to 200% 0.1% 150% 67
Additional
functions
149 Stall prevention level at 10V input 0 to 200% 0.1% 200% 67
150 Output current detection level 0 to 200% 0.1% 150% 130
151 Output current detection period 0 to 10 s 0.1 s 0 130
152 Zero current detection level 0 to 200.0% 0.1% 5.0% 131
Current
detection
153 Zero current detection period 0 to 1 s 0.01 s 0.5 s 131
154
Voltage reduction selection during
stall prevention operation
0, 1 1 1 67
155 RT activated condition 0, 10 1 0 132
156 Stall prevention operation selection 0 to 31, 100,101 1 0 132
157 OL signal waiting time 0 to 25 s, 9999 0.1 s 0 134
Sub functions
158 AM terminal function selection
1 to 3, 5 to 14,
17, 18, 21
1176
Additional
function
160 User group read selection 0, 1, 10, 11 1 0 135
162
Automatic restart after instantaneous
power failure selection
0, 1 1 0 79
163 First cushion time for restart 0 to 20 s 0.1 s 0 s 79
164 First cushion voltage for restart 0 to 100% 0.1% 0% 79
Automatic restart after
instantaneous power
failure
165
Restart stall prevention operation
level
0 to 200% 0.1% 150% 79
168
Sub
functions
169
Parameters set by the manufacturer. Do not set.
170 Watt-hour meter clear 0

0 136
Initial
monitor
171 Actual operation hour meter clear 0

0 136
173
User group 1 registration 0 to 999
10
135
174
User group 1 deletion 0 to 999, 9999
10
135
175
User group 2 registration 0 to 999
10
135
User functions
176
User group 2 deletion 0 to 999, 9999
10
135
180
RL terminal function selection
0 to 20, 22, 23,
9999
10
136
181
RM terminal function selection
0 to 20, 22, 23,
9999
11
136
182
RH terminal function selection
0 to 20, 22, 23,
9999
12
136
183
RT terminal function selection
0 to 20, 22, 23,
9999
13
136
184
AU terminal function selection
0 to 20, 22, 23,
9999
14
136
185
JOG terminal function selection
0 to 20, 22, 23,
9999
15
136
186
CS terminal function selection
0 to 20, 22, 23,
9999
16
136
190 RUN terminal function selection 0 to 199, 9999 1 0 139
191
SU terminal function selection 0 to 199, 9999 1 1 139
192
IPF terminal function selection 0 to 199, 9999 1 2 139
193
OL terminal function selection 0 to 199, 9999 1 3 139
194
FU terminal function selection 0 to 199, 9999 1 4 139
Terminal assignment functions
195
ABC terminal function selection 0 to 199, 9999 1 99 139
4
Parameter List