Operating instructions
BBV, SBV Series Natural Vent Gas Fireplaces
LIGHTING PILOT FOR THE FIRST TIME
LIGHTING PILOT
WARNING
The control has an interlock device that does not allow the lighting of the fireplace up to
the moment the safety device of the flame has not interrupted the gas flow. After that pe-
riod of time (when the magnet is closed), it is possible to start the lighting operation.
The gas control knob is designed to be operated by hand. DO NOT use any tools during
this operation. Damaged knobs may result in serious injury.
APPROVED LEAK TESTING METHOD
ou may ceck or as leaks it te olloin metods only
oap and ater solution
n approved leak testin spray
lectronic snier
WARNING
If using a soap and water solu-
tion to test for leaks, DO NOT
spray solution onto control
body.
DANGER
Never check for gas leaks with open
flame!
NOTE: Remove any excessive
pipe compound from the connec-
tions. Excessive pipe compound
can set off electronic sniffers.
eck or as leaks in eac o te olloin locations
ipe rom te as supply line connection to te as valve
urner connections ield made oints as suto valve
ilot actory made oints
ac oint or connection ll oints on valve and control body
Depress and turn knob counterclockise
to pilot
position
Depress ully and old pilot as knob e electronic i
nitor ill automatically inite te pilot eep knob ully
depressed or a e seconds elease and ceck tat
pilot continues to burn
I te pilot does not stay lit repeat teps and
TOLIP
O
F
F
P
I
L
O
T
O
N
&0
CONTROLKNOBPILOT
Figure 20 -
Pilot Position
OPERATING INSTRUCTIONS - MILLIVOLT