The compressor´s operation starting is for securing its protection, delayed by min. 3 minutes. Depending on the humidity of
environment, it may last even longer. The user must not manipulate with the setting element of a time relay.
3.4. Compressor regulation
It is necessary to make sure that the intake- and exhaust outlet are not covered. It is forbidden to place towels or clothes on the
exhaust outlet, to dry them. Cleaning the device´s cover can be done only using grooming articles suitable for rustless steel
surfaces. In case there is a water dripping from the equipment, check whether a condensate pipe is not obstructed.
At least once a year, it is necessary to have the unit checked and cleaned by a service specialist. This is necessary in order to secure a
long operational life of the device. Cleaning the interior parts of the device by a user is not recommended, as this may lead to a
damage on the unit. The device contains mobile elements as well as elements under electrical pressure, therefore the interior parts
can be cleaned only by a certified electrician with an appropriate knowlegde of refrigerating technology.
The unit must be installed in compliance with the local installation and electrical installation regulations !
6.1. Unit location
To ensure maximum efficiency, it is necessary to install the unit as high above the ground as possible.
It is essential to ensure good air circulation by allowing at least 150 mm of free space under the unit and at least 200
mm of free space above the unit. For the purpose of maintenance, it is further necessary to allow at least 200 mm of free space on
both sides of the unit.
It is forbidden to install the
unit on the floor. However it is possible to install the unit to a mobile rack, which is an accessory equipment, that can be ordered
additionally.
4. MAINTENANCE INSTRUCTIONS
5. SERVICING THE UNIT
6. INSTALLATION GUIDE
EN
The equipment has a self-supporting construction and is very easy to install.
There is an installation bracket included in the equipment accessories, which must be fixed on the wall. The axis of the fixation slots
is 210 mm lower than the top edge of the device. The distance between the fixation slots is 420 mm (DRY 300i Silver) and 360 mm
(DRY 500i Silver). When the bracket is fixed, it is possible to hang up the device without dismounting its cover.
6.2. Equipment fixation
Model DRY 300i Silver
Model DRY 500i Silver
TOP EDGE OF THE DEVICE
BRACKET
SPIRIT LEVEL
FIXATION SLOTS
The cover can be dismounted after releasing two screws (DRY 300 Silver) or three screws (DRY 500 Silver) at the bottom of the
device. Release the screws, pull the bottom part of the cover toward yourself and then, by lifting it shortly, rake down the cover from
the rear plate. To mount the cover, carry the procedure out in reverse order.
6.3. Dismounting and mounting of the cover
TOP EDGE OF THE DEVICE
BRACKET
SPIRIT LEVEL
FIXATION SLOTS
EN - WALL-MOUNTED SWIMMING POOL DEHUMIDIFIER - OWNER´S & INSTALLATION MANUAL