Operation Manual

14 DL150 Series Fixed-Format I/O Unit
1 AES clock menu
This menu lets you set up the clock source of the DL150 Series Fixed-Format I/O Unit as internal or external, for AES synchroni-
sation.
To set up the units clock source
1. In programming mode, select menu 1 (see To select a menu on page 13). The
current clock source is shown on the bottom line of the display, for example,
“Internal clock.
2. Use the down arrow to select the AES clock source you want, for example, “Ex-
ternal clock”. The bottom line will ash to show that this option is not currently
selected.
3. Press SELECT. The bottom line will stop ashing to show that this option has been selected.
4. Press MENU.
2 Set ID menu
This menu lets you set up the network ID of the DL150 Series Fixed-Format I/O Unit, which can be any number from 1 to 18.
To set up the ID of the unit
1. In programming mode, select menu 2 (see To select a menu” on page 13). The
current ID is shown on the bottom line of the display, for example, “1”.
2. Use the down arrow to go to the ID you want, for example, “7”. The ID will ash
to indicate that it is not currently selected. If you dont want to change the ID
number, go to the “Unchanged” option, which is between “1” and “18”.
3. Press SELECT.
4. Press MENU.
5. To exit programming mode, press MENU. The default display will now show the
newly congured ID number at the end of the bottom line.