installation plan

en - GB PT 5135/7135
= standard, = optional, + = only on request, - not available
10 10 145 320 / 01
Technical data
PT 5135 C
PT 7135 C
Installation on machine feet (F)
No. of machine feet
No.
4
4
Machine foot, height-adjustable with thread
mm
+14.5 / -7
+14.5 / -7
Machine foot diameter
mm
40
40
Anchoring (B)
Standard anchoring
Floor anchor kit (for 2 machine feet)
Wood screws according to DIN 571
mm
6 x 50
6 x 50
Rawl plugs (diameter x length)
mm
8 x 40
8 x 40
Anchoring of Miele plinths
Miele plinth installation (fasteners included)
Required anchor points
No.
4
4
Wood screws according to DIN 571
mm
8 x 65
8 x 65
Rawl plugs (diameter x length)
mm
12 x 60
12 x 60
Plinth floor anchoring (to be provided on site)
Machine installation on permanent plinth (concrete or masonry)
Plinth installation footprint (W/D)
mm
600/650
600/650
Wood screws according to DIN 571
mm
6 x 50
6 x 50
Rawl plugs (diameter x length)
mm
8 x 40
8 x 40
Machine data
Overall machine dimensions (H/W/D):
mm
850/600/709
850/600/709
Casing dimensions (H/W/D)
mm
850/595/697
850/595/697
Site-access dimensions (H/W)
Min. site-access (excl. packaging)
mm
900/600
900/600
Installation dimensions
Min. side gap
mm
20
20
Recommended side gap - washer-dryer stack
mm
300
300
Recommended min. distance to opposite wall from machine front
mm
900
900
Recommended distance to opposite wall from front of machine
mm
1100
1100
Weights and floor loads
Machine weight (net weight)
kg
57
57
Max. floor load in operation
N
720
720
Emissions
Sound pressure level in accordance with EN ISO 11204/11203
dB(A)
< 70
< 70
Heat dissipation rate to installation site
W
2500
2500