installation plan

PT 5135/7135 en - GB
= standard, = optional, + = only on request, - not available
10 145 320 / 01 9
Technical data
PT 5135 C
PT 7135 C
Standard voltage (FIN only)
-
2N AC 400 V
Frequency
Hz
-
50
Total rated load
kW
-
3.68
Fuse rating (B trip rating according to EN 60898)
A
-
2 x 10
Supply lead min. cross-section
mm²
-
4 x 1.5
Supply lead without plug for hard-wired connection
-
Length of supply lead
mm
-
2000
Alternative voltage (convertible)
1N AC 230 V
Frequency
Hz
-
50
Total rated load
kW
-
3.68
Fuse rating (B trip rating according to EN 60898)
A
-
1 x 16
Supply lead min. cross-section
mm²
-
3 x 1.5
Alternative voltage (convertible)
1N AC 230 V
Frequency
Hz
-
50
Total rated load
kW
-
2.17
Fuse rating (B trip rating according to EN 60898)
A
-
1 x 10
Supply lead min. cross-section
mm²
-
3 x 1.5
Standard voltage (AUS only)
-
1N AC 230-240 V
Frequency
Hz
-
50
Total rated load
kW
-
2.17 2.34
Fuse rating
A
-
1 x 10
Supply lead min. cross-section
mm²
-
3 x 1.0
Supply lead with plug
-
Length of supply lead
mm
-
2000
Standard voltage (J only)
-
1N AC 200 V
Frequency
Hz
-
50 60
Total rated load
kW
-
3.7
Fuse rating
A
-
1 x 20
Supply lead min. cross-section
mm²
-
3 x 2.75
Supply lead with plug
-
Length of supply lead
mm
-
2000
Condensate drain hose (ASK)
Drainage temperature, max.
°C
70
70
Max. transient flow rate
l/min
3.6
3.6
On-site hose sleeve for drain hose (outer dia. x length)
mm
10 x 30
10 x 30
Drain hose (internal diameter)
mm
10 (DN10)
10 (DN10)
Drain hose length
mm
1800
1800
Drain pump head height from bottom edge of machine, max.
mm
1000
1000
Cooling air intake (KLZ)
Air flow must remain unobstructed at all times
Cooling air discharge vent (KLA)
Air flow must remain unobstructed at all times
Equipotential bonding (PA)
Machine connection (separate kit required)
Peak load/energy management (SLA)
Machine connection (separate kit required)
Control signal voltage
230 V
230 V
Payment system connection (KGA)
Connection of payment systems
Communication module (XKM)
RS 232 serial interface (XKM module retrofitting kit)