Installation plan

PWM 908 en-US
= standard, = optional, + = only on request, - not available
11 282 580/05 13
Technical data
PWM 908 DP
PWM 908 DP
Drum volume
19.3
gal
73
l
Capacity
19.8
lb
9.0
kg
Door opening diameter
11 13/16"
300
mm
Max. spin speed
1,600
rpm
1,600
rpm
g-factor
613
613
Residual moisture (standard load according to DIN 60456)
48
%
48
%
Electrical connection (EL)
Standard voltage for CDN & USA
2 AC 208240 V
2 AC 208240 V
Frequency
60
Hz
60
Hz
Total rated load
4.05.2
kW
4.05.2
kW
Fuse rating
2 x 30
A
2 x 30
A
Power cord min. cross-section
3 x AWG10
3 x AWG10
Wire with plug NEMA L630
Wire length
78 3/4"
2,000
mm
Non-standard voltage MAR 208240 (Marine)
2 AC 208240 V
2 AC 208240 V
Frequency
60
Hz
60
Hz
Total rated load
4.05.2
kW
4.05.2
kW
Fuse rating
2 x 30
A
2 x 30
A
Power cord min. cross-section
3 x AWG10
3 x AWG10
Wire with plug NEMA L630
Wire length
78 3/4"
2,000
mm
Cold water (KW)
Permissible water flow pressure
14.5145
PSI
1001,000
kPa
Required flow rate (cold water connection only)
2.9
gal/min
11
l/min
Required flow rate (with additional hot water connection)
2.6
gal/min
10
l/min
Average water consumption (60°C standard programme)
10.5
gal/h
40
l/h
Connection to be provided on site, external thread according to DIN 44991 (flat seal)
¾"
¾"
Connection hose ½" with ¾" threaded union
Connection hose length
61"
1,550
mm
Hot water (WW)
Max. water intake temperature
158
°F
70
°C
Permissible water flow pressure
14.5145
PSI
1001,000
kPa
Required flow rate
2.9
gal/min
11
l/min
Average water consumption (60°C standard programme)
3.4
gal/h
13
l/h
Connection to be provided on site, external thread according to DIN 44991 (flat seal)
¾"
¾"
Connection hose ½" with ¾" threaded union

Connection hose length
61"
1,550
mm
Drain pump (DP)
Hose connection (external diameter)
7/8"
22 / DN22
mm
Max. drainage temperature
194
°F
90
°C
On-site hose sleeve (int. diameter x length)
22 x 30
mm
22 x 30
mm
Max. transient flow rate
6.8
gal/min
26
l/min
Max. delivery head (from lower edge of machine)
39 3/8"
1,000
mm
Drain hose DN 22 with connector (supplied as standard)
Connection hose length
59 1/16"
1,500
mm
Potential equalization (PA)
Machine connection (separate kit required)

Features available via the XCI-Box accessory
Peak load/energy management

Payment system connection

Liquid dispensing (DOS)

Possible no. of dispensing pumps
16
16