Installation plan

PWM 908 en-US
= standard, = optional, + = only on request, - not available
14 11 282 580/05
Technical data
PWM 908 DP
PWM 908 DP
Installation on machine feet (F)
No. of machine feet
4
No.
4
No.
Machine foot, height-adjustable with thread
+5/16"
+8
mm
Machine foot diameter
1.57”
40
mm
Anchoring (B)
Standard floor anchoring
Floor anchor kit (for 2 machine feet) with anchors
Wood screws according to DIN 571
6 x 50
mm
6 x 50
mm
Rawl plugs (diameter x length)
8 x 40
mm
8 x 40
mm
Anchoring of Miele Plinths
Accessory: Miele Plinth installation (fasteners included)
Required anchor points
4
No.
4
No.
Wood screws according to DIN 571
8 x 65
mm
8 x 65
mm
Rawl plugs (diameter x length)
12 x 60
mm
12 x 60
mm
Plinth floor anchoring (to be provided on site)
Machine installation on on-site plinth (concrete or masonry)

Min. plinth installation footprint (W/D)
23 5/8" / 25 9/16"
600/650
mm
Wood screws according to DIN 571
6 x 50
mm
6 x 50
mm
Rawl plugs (diameter x length)
8 x 40
mm
8 x 40
mm
Machine data
Overall machine dimensions (H/W/D)
33 15/32" / 23 13/16" / 28 7/64"
850/605/714
mm
Casing dimensions (H/W/D)
33 15/32" / 23 7/16" / 26 11/16"
850/596/678
mm
Site-access dimensions (H/W)
Min. site-access opening (excl. packaging)
35 7/16" / 23 13/16"
900/605
mm
Installation dimensions
Side gap
13/16"
20
mm
Recommended side gap washer-dryer stack
11 13/16"
300
mm
Recommended distance to opposite wall from front of machine
39 3/8"
1,000
mm
Weights and floor loads
Machine weight (net weight)
227
lb
103
kg
Max. floor load in operation
2,820
N
2,820
N
Max. floor load, static
1,380
N
1,380
N
Max. floor load, dynamic
1,365
N
1,365
N
Emissions
Sound pressure level (in accordance with EN ISO 11204/11203)
<70
dB(A)
<70
dB(A)
Heat dissipation rate to installation site
250
W
250
W