Product Manual

22 Milbank Manual Transfer Switch Owner’s and Installation Manual
QUICK START GUIDE
GENERATOR MODE
UTILITY MODE
PHASE A
PHASE B
The digital monitor on the Milbank Manual Transfer Switch is an added tool that
enables the user to safely use their portable generator and reduce the chance of an
overload condition. To effectively utilize this option we have included a learn function
in the MTS that will allow you to calibrate the switch for the size of generator you are
using.
OPERATING ON UTILITY OPERATING ON GENERATOR
Phase A
near max
Phase A
near max
both
phases are
using more
power than
generator
can provide.
both phases
are using
more power
than generator
can provide.
Try to move some loads from
A-B to Balance the Generator
Must turn off loads before
switching to Generator or
overload
Well-balanced OK, but only turn on
Phase B circuits
If Generator “sounds” OK,
then process the “LEARN
FUNCTION” again
The digital monitor on the Milbank Manual Transfer Switch is an added tool that enables the user to safely use
their portable generator and reduce the chance of an overload condition. To effectively utilize this option we have
included a learn function in the MTS that will allow you to calibrate the switch for the size of generator you are
using.