Product Manual

Milbank Manual Transfer Switch Owner’s and Installation Manual 23
QUICK START GUIDE
Until Generator is “Full”
150%
0%
to set MMTS to Factory setting (10kw) - hold “learn” for 15 sec.
Learn Complete
Q: Sometimes the lights blink faster than other times.
A: Each light will blink slowly when it is at the bottom of its ‘range’ and blink
fast when it is near the top of its ‘range’. Once it goes on solid, then the
LED on top of it will start blinking.
Q: How do I know my generator is near capacity?
A: Listen to it – it will sound like a manual transmission car in too high a gear,
lugging and slowing down
A: Watch the lights – they will start to dim or flicker when the generator is
over-capacity
Q: The GFCI trips on the Generator every time I switch to it.
A: Your generator needs to be converted from ‘portable’ mode to
‘permanent’ or ‘installed’ mode. Consult your generator manual to defeat
the GFCI, but ONLY while it is connected to your house.
NO POWER
OR
NO LOAD ON
PHASE A OR B
GENERATOR ON
UTILITY POWER OFF
1. MOVE SWITCH
2. MAKE SURE
SOME LOADS ARE
TURNED ON
The digital monitor on the Milbank Manual Transfer Switch is an added
tool that enables the user to safely use their portable generator and
reduce the chance of an overload condition. To effectively utilize this
option we have included a learn function in the MMTS that will allow
you to calibrate the switch for the size of generator you are using.