Standard Model
8 in. (20 cm)
w/HEPA Filter Option
24 in. (61 cm)
w/Weather Hood Option
12 in. (30 cm)
Minimum clearance requirements
are the same for all models.
5-2. Clearance Requirements
254 235-B
8 in. (20 cm)
36 in. (91 cm)
36 in. (91 cm)
! Lift only from the lifting eyes
located at the top of the unit.
Be sure location is clear of all
obstructions, including utility
lines and roof overhangs.
1 Lifting Eyes
2 Spreader Bar
3 Fixed Length Lifting Straps
Use all lifting points provided. Use
clevis connectors, not hooks, on lift-
ing lugs.
Use spreader bars to prevent dam-
age to unit. Use fixed length lifting
straps to connect to spreader bar(s).
See the Specifications in Section 4-4
for weight and dimensions of the unit
and to ensure lifting equipment is of
adequate capacity.
Lift unit and accessories separately,
and assemble after unit is in place.