Instruction manual

Adaptto E-drives Lab. 2013
8.Charging and DCDC mode connection
To charge your battery via regen-charging mode you must connect PSU (Power Supply
Unit) to the controller via Inductor according to the following picture.
Inductor L1 must be 15-30uH with sufficient current rating (>than PSU max current)
Capacitor C1 must be 470-1000uF with voltage greater than PSU voltage
Left side of L1 connected to ANY of 3 phase wires, while they still must be connected to
the motor. Negative lead of the PSU must be connected to Negative Charging lead of the
controller (black female XT150 connector)
In charge mode when Charge is enabled and PSU connected, charging will start
automatically. For setting Charge parameters please see page 8 <Charge setup> menu.
In DC-DC mode load must be connected instead of PSU, but L1 and C1 is mandatory.
13