Instruction manual

FAULT FINDING
Air Valve Plate (item
33) or Air Valve (item
38) damaged.
Diaphragm (item 31)
damaged
Cyl Head screws loose
(item 42)
Air hose leaking
Cyl Head Screws too
tight.
Bearing Fault
Cyl Head Screws too
tight.
Armature faulty
Armature faulty
Thermal cut-out has
operated
Renew defective Air Valve
Plate or Air Valve.
Renew Diaphragm
Tighten screws to 10 lbf ft
Check seal or renew Air
Hose
Back off all screws and
tighten equally.. .to 10 lbf ft
Consult your Clarke dealer
Back off all screws and
tighten equally.. .to 10 lbf ft
Consult your Clarke dealer
Consult your Clarke dealer
Switch OFF and
disconnect. Wait for 15-20
mins and try again.
Low air flow
Noisy operation
Compressor
hums but does
not work.
Compressor
does not work.
PROBLEM PROBABLE CAUSE REMEDY
SPECIFICATIONS
Motor ............................................................... 230V 50Hz 1 Ph
Power Rating .................................................. 1/8HP
Rotational Speed ........................................... 1500RPM
Max Pressure ................................................... 40psi
Air Displacement ............................................ 1.58 cuft/min
Fuse Rating ...................................................... 13amps
Cyl. Head Bolt torque setting ....................... 10 lbf ft
Weight ............................................................. 4.3kg
7