ARTEMIS TM A U.S.
This product is protected by United States Federal and/or State Law including Patents, Trademark, and/or Copyright Laws. ©2017 Minka Lighting Inc. Manual design and all elements of manual design are protected by United States Federal and/or State Law including Patents, Trademark, and/or Copyright Laws.
The Minka-Aire® warranty is for one (1) year from the date of purchase from an authorized Minka-Aire® dealer. This warranty is only valid to the original purchaser or user against all defects in material and workmanship (light bulbs excluded) for one (1) full year. Additionally, Minka-Aire® warrants the motor only for the lifetime of the Minka Aire ceiling fan (excluding wall controls and electrical components), to the original purchaser or user.
Warranty Service Information To obtain warranty service during the warranty period, the purchaser should return the fan with the sales receipt to the original place of purchase. The authorized Minka-Aire® dealer, at its sole discretion, will either repair or replace the fan after verifying the legitimacy of the warranty claim. Replacement is subject to availability of the same model. If the model is unavailable it will be replaced by one of equal value.
SAFETY RULES.................................................................................... 1 BLADE INSTALLATION.......................................................................................8 PACKAGE CONTENTS..................................................................... 2 INSTALLING THE MOUNTING PLATE......................................................... 9 INSTALLING THE FAN.....................................................................3 INSTALLING THE LED LIGHT KIT.......
1 SAFETY RULES 1. Before you begin installing the fan, shut power off at the circuit breaker of the fuse box. 2. Be cautious! Read all instructions and safety information before installing your new fan. Review accompanying assembly diagrams. 3. Make sure that all electrical connections comply with local codes, ordinances, or National Electrical Codes. Hire a qualified electrician or consult a do-it-yourself wiring handbook if you are unfamiliar with installing electrical wiring. 4.
ATTENTION: The Energy Policy Act of 2005 requires this fan to be equipped with a 75 watt limiting device. If lamping exceeds 75 watts, the ceiling fan's light kit will shut off automatically. NOTE: The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and care are factors which can not be built into this product.
2 PACKAGE CONTENTS 2 Unpack your fan and check the contents. You should have the following items: 1. Fan blades (3) 2. Hanger bracket 3. Canopy 4. Canopy cover 5. Downrod assembly 6. Coupling cover 7. Fan motor/housing assembly 8. Mounting plate 9. 17W LED Light kit 10. Glass shade 11. Optional switch cup cover 12. Receiver with 6 wire nuts 13a. Wall transmitter Incl. 2 mounting screws and 3 wire nuts 13b. Wall plate w/2 mounting screws 14. Extra Wall Plate w/2 Mounting screws A.
Tools Required: Phillips screw driver; slotted screw driver; step-ladder; wire cutters; electrical tape. MOUNTING OPTIONS INSTALLING THE FAN OUTLET BOX If there isn't an existing mounting box, then read the following instructions. Disconnect the power by removing fuses or turning off circuit breakers. Secure the outlet box directly to the building structure. Use appropriate fasteners and building materials.
4 HANGING THE FAN WARNING: All of the parts, hardware and components such as the hanger bracket and hanger ball have been provided for your safety and the proper installation of your new ceiling fan. The use of other parts, hardware or components not supplied by Minka Aire® with the fan will void the Minka Aire® Warranty. REMEMBER to turn off the power. Follow the steps below to hang your fan properly: Step 1.
DOWNROD OUTLET BOX CROSS PIN DOWNROD SET SCREW SUPPLY WIRES CANOPY SET SCREWS HITCH PIN LOCK PIN COUPLING COVER HANGER BALL CANOPY COVER REGISTRATION SLOT SET SCREWS DOWNROD HANGER BRACKET Fig. 5 Fig. 6 Fig. 7 Fig. 10 Fig. 8 LOCK PIN Fig.
5 ELECTRICAL CONNECTIONS WARNING: To avoid possible electrical shock be sure electricity is turned off at the main fuse or breaker box before wiring. NOTE: The Aire Control® System is equipped with a learning frequency function which has 256 code combinations to prevent potential interference from other remote units. The frequency on your Receiver and Transmitter units have been preset at the factory. (Fig.
Step 3. Receiver to House Supply Wires Electrical Connections: Connect the WHITE wire (Neutral) from the outlet box to the WHITE wire marked "AC in N" from the receiver. Connect the BLACK wire (Hot) from the outlet box to the BLACK wire marked "AC in L" from the receiver. Secure all wire connections with the plastic wire nuts provided. (Fig. 13 & 14) Step 4. If your outlet box has a GROUND wire (Green or Bare Copper) connect this wire to the Hanger Ball and Hanger Bracket Ground wires.
WHITE AC SUPPLY BLACK BLUE (FOR LIGHT) BLACK (MOTOR) ORANGE (FOR UPPER LIGHT) BLACK BLACK BLUE BLACK WHITE ORANGE Fig. 13 GROUND Fig. 14 GREEN WHITE GROUND ORANGE BLUE BLACK WHITE ("TO MOTOR N") GROUND- (CONNECT TO (GREEN) GROUND WIRE ON HANGER BRACKE IF NO HOUSE GROUND WIRE EXISTS.
INSTALLING THE WALL TRANSMITTER WARNING! HOOK UP "IN SERIES" ONLY. DO NOT CONNECT NEUTRAL SUPPLY WIRE OF ELECTRIC CIRCUIT TO THE TRANSMITTER WALL SWITCH, DAMAGE TO THE TRANSMITTER WALL SWITCH AND POSSIBLE FIRE COULD OCCUR. Step 1. Remove the existing wall plate and switch from the wall outlet box. Step 2. Make the electrical connections as shown in Fig.14. If your outlet box has a ground wire (Green or Bare Copper) connect the Transmitter's ground wire directly to one of the screws from the outlet box.
7 FINISHING THE INSTALLATION Step 1. Remove 1 of the 2 screws from the bottom of the hanger bracket and loosen the other one half a turn from the screw head. Step 2. Slide the canopy up towards the hanger bracket and place the key hole on the canopy over the screw on the hanger bracket, turn canopy until it locks in place at the narrow section of the key holes. (Fig. 16) OUTLET BOX HANGER BRACKET HANGER BALL Step 3.
8 BLADE INSTALLATION Align and engage the top holes from one of the blades to the upper blade holder tabs. Carefully align the bottom holes from the blade to the holes from the lower blade holder. Secure blade with 3 screws and washers provided. Follow the same process for the remaining two blades. (Fig. 17) UPPER BLADE HOLDER TABS All blade sets are grouped together by weight. Because plastic materials vary in density, the fan may wobble even though the blades are weight matched.
9 INSTALLING THE MOUNTING PLATE Step 1. Remove 1 of 3 screws from the mounting ring and loosen the other 2 screws. (Do not remove) Step 2. Place the key holes from the mounting plate over the 2 screws previously loosened from the mounting ring, turn mounting plate until it locks in place at the narrow section of the key holes. Secure by tightening the 2 screws previously loosened and the one previously removed. (Fig.
10 INSTALLING THE LED LIGHT KIT NOTE: Before starting installation, make sure power is turned off at the circuit breaker. Step 1. Remove one of the three mounting screws from the mounting plate and loosen the other two screws. (Do not remove.) Step 2. While holding the LED light kit under the fan motor assembly, make the 2-pin wire connections: (Fig. 19) - White to white - Black to black Step 3.
11 INSTALLING THE GLASS SHADE ATTENTION: The Energy Policy Act of 2005 requires this fan to be equipped with a 75 watt limiting device. If lamping exceeds 75 watts, the ceiling fan's light kit will shut off automatically. Step 1. Raise the glass shade or optional switch cup cover up against the LED light kit and secure it to the fan by turning glass shade clockwise untilsnug. DO NOT OVERTIGHTEN. (Fig.
OPERATING THE REMOTE CONTROL/WALL CONTROL Remote Control only: Install a A23 12 volt battery (included). To prevent damage to transmitter remove the battery if not used for long periods of time. instructions apply to ceiling fans that feature a DOWN D. OFF-ON Slide Button (Wall Control Fans Only) light ( button) only or ceiling fans that feature an UP This button turns the power Off and On to the Fan and A. Buttons: light ( button) and a DOWN light ( button) that are Light(s).
Speed settings for warm or cold weather depend on factors such as room size, ceiling height and number of fans. NOTE: to change the direction of the rotation of the blades the fan must be in operation mode. Warm Weather (forward) A DOWNWARD airflow creates a cooling effect as shown in Figure 21. This allows you to set your air conditioner on a warmer setting without affecting your comfort. Cool Weather (Reverse) An UPWARD airflow moves warmer air off the ceiling area as shown in Figure 22.
CARE OF YOUR FAN Here are some suggestions to help maintain your fan. 4. Use a lint free lightly damp cloth or duster to remove dust from the blades. 1. Because of the fan's natural movement some connections may become loose. Check the support connections, brackets and blade attachments twice a year. Make sure they are secure. (It is not necessary to remove fan from the ceiling). 5. There is no need to oil your fan. The motor has permanently lubricated bearings. 2.
14 TROUBLESHOOTING SYMPTOM Fan will not start SOLUTION Check to make sure the wall switch is turned on. Check circuit fuses or breakers. Caution! Make sure the power is turned off before performing the following steps. SYMPTOM Fan Sounds Noisy SOLUTION Allow a 24-hour "break in" period. Most noises associated with a new fan will go away during this time. Make sure the screws that attach the fan blade holder to the motor hub is tight. Remove canopy and check wire connections.
SYMPTOM Fan Wobble SOLUTION NOTE: All blade sets are grouped by weight. Make sure outlet box is secured to building structure, if necessary use the wood screws provided to further secure outlet box to joist. Make sure hanger bracket is secure to the outlet box, screws are tight. If a Balancing kit is provided follow the instructions included with the balancing kit to help correct any excessive wobble. SYMPTOM Lights shut off and will not come back on.
SYMPTOM Frequency Interference SOLUTION 1. Turn the power off to your ceiling fan. 2. Please use a small size tool to change the frequency settings on the control system. 3. Return power to the unit. Note: After the AC power is on, do not press any other button on the transmitter before pressing the "Stop" button, doing so will cause the procedure to fail. 4. Within 60 seconds of turning the Fan's AC power ON. Press the transmitter's "Stop" button and hold the "Stop" button for 10 seconds. 5.
SPECIFICATIONS These are typical readings. Your actual fan may vary. They do not include amps and wattage used by the light(s). Fan Size 58" Speed Volts Amps Watts RPM Low 120 0.373 21.20 69 High 120 0.798 94.35 132 N.W. G.W. C.F. 11.57 13.84 3.
PERFORMANCE AND ENERGY INFORMATION FAN SPEED Low High Estimated Yearly Energy Cost $17 $3 Airflow 3,983 Cubic Feet Per Minute AIRFLOW (CFM)* POWER USE AIRFLOW EFFICIENCY 21.20 94.35 122 56 2587 5284 (Watts) Ceiling fan airflow is measured in cubic feet per minute (CFM). Power use is measured in watts. To maximize energy savings: • Choose a fan with high airflow efficiency (CFM/watt). * Measure according • Use ENERGY STAR® rated bulbs in your fan. • Switch off your fan when you leave the room.