Installation Guide

INSTALLATION INSTRUCTIONS
Item# 4555-588
READ AND SAVE THESE INSTRUCTIONS
W A R N I N G ! S H U T P O W E R O F F AT F U S E O R C I R C U I T B R E A K E R .
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.
Page: 1/2
Fig. 1
Fig. 3
PREPARATION (Fig. 1)
1.
2.
ASSEMBLING THE FIXTURE WITH CHAIN LOOP (Fig. 2)
4.
By measuring, determine desired hanging height and thread rods
(F1, F2 and F3) onto nipple (S), then attach to loop (H1) by
screwing in rod (F1). Carefully pass the wire through each rod
during assembly. Note: remove the nipple if installing with one 6”
rod only.
CONNECTING THE WIRES (Fig. 3)
COMPLETING THE INSTALLATION (Fig. 1)
Your installation is now complete. Return power to the
junction box and test the fixture.
Note:
Illustration (Fig. 1) on this manual is for
installation purposes only. It may or may not be
identical to the fixture purchased.
FIXTURE
WIRES
Black or
Smooth
HOUSE
WIRES
Black
(Hot)
FIXTURE
WIRES
White or
Ribbed
HOUSE
WIRES
White
(Neutral)
FIXTURE
WIRES
Bare
Copper
(Ground)
HOUSE
WIRES
Green
(Ground)
Set
-Crossbar
-Ground screw
-Mounting Screw*2
F1
A-010
Rod#
W30-1-281*2(F2)
W30-H-281*1(F3)
W30-1-281*1(F1)
Outlet Box
B
P
C
D
E
H2
Q1
Q2
G
H1
A
F2
F3
J
J
R
L
N
K
M
S
Carefully remove the fixture from the carton and check that all
parts are included as shown in the illustration.
Shut off the power at the fuse box or circuit breaker. If necessary,
remove the old fixture including the mounting hardware.
Adjust the steel cable (J) to keep fixture leveled. Note: Press
spring coupling (R) by hand and adjust the steel cable (J) to
the desired length.
8. Slide the canopy (D) and ceiling loop collar (E) onto the quick link
(G), attach the quick link (G) connect to fixture loop (H1) and
ceiling loop (H2), carefully feed the wire over fixture loop (H1),
quick link (G) and ceiling loop (H2).
Place the hex nut (Q1) over the end of nipple (C), thread the
nipple (C) into ceiling loop (H2) until snug, then thread the hex
nut (Q1) until tight.
Place the hex nut (Q2) and lock washer (P) over the other end
of nipple (C) and thread the other end of the nipple (C) into the
crossbar (A) until snug, and thread hex nut (Q2) until tight. Note:
The length of the nipple into the crossbar may be adjusted if
necessary.
Take this crossbar asselbly and mount it to celing outlet box with
mounting screws (Size: #8-32N*L0.5”). Tighten screws securely
with screwdriver (not included). The side of crossbar marked
“GND” must face out.
5.
6.
7.
9.
At this point, connect the electrical wires as shown in figure 3,
making sure that all wire connectors are secured. If your outlet
has a ground wire (green or bare copper), connect the fixture’s
ground wire to it. Otherwise, connect the fixture’s ground wire
directly to the crossbar using the green screw provided. Tuck
the wire connections neatly into the ceiling outlet box and then
raise the canopy (D) all the way to the ceiling. Thread the loop
collar (E) to the ceiling loop (H2) to secure the canopy (D) against
the ceiling.
3.
10.
Place the glass shade (N) over socket cup (L). Using screws (M)
secure glass shades to socket cap above socke cup (L).
Install the light bulb(s) (K) (supplied) in accordance with the
fixture’s specifications. (DO NOT EXCEED THE MAXIMUM
WATTAGE RATING!) (NE PAS DEPASSER LA PUISSANCE
NOMINALE MAXIMALE!).
11.

Summary of content (2 pages)