Troubleshooting guide

Table Of Contents
112
3300 ICP Technician’s Handbook
6. Choose to Reboot immediately or Reboot manually later. You must
reboot your system for the patch installation to take effect.
7. The patch installation completes.
Distributing New Firmware to IP Phones
Use this procedure to distribute IP Phone firmware after you upgrade any
controller in a resilient cluster.
1. Wait for all IP devices to return to their primary ICP (now upgraded).
2. Use the LOAD IPDEVICE 1 to 300 maintenance command to force a
firmware reload of all devices.
Load IP Phone Software Remotely
Use the LOAD IPDEVICE maintenance command to transfer IP Phone
software to the IP Phones. Because the 3300 ICP supports a maximum of
300 TFTP connections at any one time, you must issue the command
multiple times to load software to a large number of IP devices. For
example to load software to 500 IP devices, you must issue the command
twice:
LOAD IPDEVICE 1 TO 300
LOAD IPDEVICE 301 TO 500
Use the IPDevice <1>, <2>...<1400> qualifier to load software into an
individual IP device.
Use the IPDevice <1 TO 300> qualifier to load software into all IP devices
(up to 300 devices at a time)
If IP Phones fail to load software:
1. Verify the network connection.
2. Verify power (is there a display?).
3. Check the wiring.
Note: The Load command uses TFTP connections to transfer software to
IP devices.Because the 3300 ICP supports a maximum of 300 TFTP
connections at any one time, you must issue the command multiple times
to load software to a large number of IP devices. For example to load
software to 500 IP devices, you must issue the command twice:
LOAD IPDEVICE 1 TO 300
LOAD IPDEVICE 301 TO 500