Troubleshooting guide

Table Of Contents
198
3300 ICP Technician’s Handbook
8. Complete the remaining cable connections as follows (refer to Figure
62 (page 196) above for connector locations):
- Connect the loose end of the Ethernet cable to the Ethernet jack on
the APC-CX(i) II Assembly to the corresponding jack on the main
board; (5) in Figure 62 (page 196).
- Connect the loose end of the housekeeping signal cable on the
APC-CX(i) II Assembly to the corresponding connector on the main
board. The connectors are keyed for proper connection; (4) in
Figure 62 (page 196).
Ensure that the housekeeping cable goes over the Ethernet cable
as shown in Figure 65. This is to avoid damage to the cable from
heat produced by the nearby transformer.
Figure 65: Cable Routing
Housekeeping cable
goes over Ethernet
cable