Troubleshooting guide

Table Of Contents
213
Install and Replace Units
15. To copy data onto the second new hard drive, complete steps 11 to 13
of the “Replace One Hard Drive in an MXe II/MXe Server” procedure
on page 210.
Replace Both Hard Drives in an MXe Server
Use this procedure if:
- both drives are defective, or
- the system is still under warranty, or
- the current and replacement drives are different sizes.
To replace both hard drives in an MXe Server:
1. Ensure that you have a database backup (if possible).
2. Loosen the captive screws and slide the hard drives from the hard
drive carrier.
3. Clear the sockets (refer to Knowledge Base Article 06-2806-00012).
4. Replace the old hard drive with the new hard drive in the hard drive
carrier and secure with the four screws.
5. Slide the first hard drive into the HD1 position. DO NOT INSTALL the
second hard drive at this time.
6. Push to seat the first hard drive into the hard drive backplane.
7. Tighten the thumb screw.
8. Return power to the controller.
9. Once the system is booted, install and configure Mitel Standard Linux
(MSL) software on the hard drive (see “Installing MSL Software on an
MXe Server” on page 106).
10. Reconnect the controller to the network.
11. Replace the second old hard drive with the second new hard drive in
the hard drive carrier and secure with the four screws.
12. Slide the second hard drive into the HD2 position.
13. Push to seat the hard drive into the hard drive backplane.
14. Tighten the thumb screw.
CAUTION: You must install only the first hard drive before
you boot the system. After the system is fully booted, slide
the second hard drive into the HD2 position.