Troubleshooting guide

Table Of Contents
338
3300 ICP Technician’s Handbook
Request off-line OFF GREEN flashing
(1/sec)
Button pushed while
online
Going off-line OFF GREEN Button released,
processing request
Off-line OFF OFF
Request on-line Note GREEN flashing
(1/sec)
Coming on-line OFF OFF Button released,
processing
Drive removed ORANGE OFF Replace drive and
rebuild
Drive reinserted ORANGE OFF Perform rebuild
Request rebuild Note GREEN flashing
(2/sec)
Rebuilding GREEN
flashing
GREEN Button released,
processing; may take 6
hours
Rebuild
complete
OFF GREEN Resume normal
operation
Soft fault ORANGE
flashing
GREEN Read fault
Hard fault ORANGE OFF Replace drive and
rebuild
Note: Depends on previous LED state:
OFF = Online; ORANGE = Fault.
Table 71: MXe II/MXe Server RAID Fault and Access LEDs
Hard Drive
State
Fault Access Description
Page 2 of 2