Troubleshooting guide

Table Of Contents
340
3300 ICP Technician’s Handbook
FIM
The top LED indicates the status of local FIM. The bottom LED indicates
the status of the remote FIM.
The controller FIM monitors the synchronization of the clock appearing on
the fiber link from the peripheral cabinet or DSU. The FIM in the peripheral
cabinet or DSU monitors the synchronization of the clock appearing on the
fiber link from the controller.
Failure BLUE Slow BLUE
flashing
HD 2 failed or out of
date
Slow BLUE
flashing
BLUE HD 1 failed or out of
date
Mismatch BLUE BLUE flashing
SOS signal
(Three quick flashes
followed by three slow
flashes)
HD 2 was swapped but
does not match
BLUE flashing
SOS signal
BLUE HD 1 was swapped but
does not match
Table 74: Controller FIM LEDs (LX)
LED Status Meaning (Both LEDs)
ON In-frame synchronization.
Flashing Out of synchronization OR Tx and Rx fiber optic cables
reversed.
OFF Power off OR held in reset.
Table 73: MXe III RAID Link LEDs (continued)
Hard Drive
State
HD 1 HD 2 Description
Page 2 of 2