Table Of Contents
63
Installation and Programming
2. Remove all trunk interface cards and other unsupported cards from
the SX-200 Bay.
3. Install the SX-200 Bay, including the Bay Power Supply, Bay Control
Card, interface cards, Fiber or Copper Interface Module, and DSP
Module (Single).
4. Complete the peripheral interface cabling. See Table 47 on page 267
for cable connector pinouts.
CIM Connection
5. Connect a Crossover Category 5 cable with RJ-45 connector to the
CIM port on SX-200 Bay and a free CIM port on the controller (see
Table 33 on page 256).
FIM Connection
6. Connect a fiber optic cable between the SX-200 Bay and the controller
FIMs.
Note: The 3300 ICP lacks dedicated hardware and software support for the
Door Opener facilities available on the SX-200 ICP. Equivalent functionality
can be provisioned by using the loudspeaker paging feature and the
associated paging relays on the AOB or AMB.
Note: The maintenance port on the SX-200 Bay is not required as all Bay
programming and maintenance is done through the System Administration
Tool on the 3300 MXe.
Note: The single DSP Module is required to support ONS CLASS/CLIP sets.
Tip: The SX-200 Bay can be located up to 30 meters (100 feet) away from the
controller. The interface uses a single standard 8-pin modular jack consisting
of 2 balanced signal pairs, and is located on the front of the BCC III card.
Note: The same variant of fiber interface module (820 nm multi-mode, 1300
nm multi-mode, or 1300 mn single-mode) must be at both ends.
Note: No other type of peripheral unit (NSU, DSU, etc.) can be connected
to a Dual FIM module that is being used by a 200 Bay. The only type of
unit allowed is another 200 Bay.