Troubleshooting guide

Table Of Contents
86
3300 ICP Technician’s Handbook
1. Back up the 3300 ICP database to the Installer PC (page 130).
2. Install the software on the FTP Server (page 106).
3. Connect the maintenance PC to the controller (page 13).
4. Launch your VT100 emulator communications program.
5. Power up the controller.
6. Stop the controller from booting by responding to the prompt:
-Press <SPACE><SPACE><SPACE> to stop auto-boot AFTER
countdown starts (Release 5.2 and later)
- Press any key to stop auto-boot (prior to Release 5.2).
7. At [VXWorks Boot], type c, and press ENTER.
8. For each setting shown in bold (Table 7 below), type the table value,
then press ENTER. For all other settings, press ENTER to accept the
default value.
CAUTION: If you have a Universal NSU with a PRI database,
you may need to convert that database before you begin the
upgrade. Refer to “Converting a PRI Database on a Universal
NSU” on page 138 and the RN for conditions.
Tip: The VXWorks parameters are case-sensitive.
Table 7: VxWorks Settings
Prompt Value Note
boot device qefcc
(CX(i) II and MXe III)
—or—
motfcc
(all other controllers)
Boot device is Network.
Note: The CX(i) II and MXe III
accept motfcc but automatically
convert it to qefcc on the next
system reboot.
processor number 0 Not used.
host name bootHost
file name Boot_Install Boot location and file name.