Specifications

17
•PFAV-P900VM-E-F
LEV3
LEV2 LEV1
(Shield)
N
Indoor controller board No.2
TH21
TH21
31
123456
SW14
SW12
SW11
Indoor/Outdoor
transmission line
M1
S
M2
2
1
CN2M
CNP
1
3
CN20CN28
1212
X4
TH22 TH23 TH24
2121
CN29
21
CN21
CN22
CN3A
2
1
CN2M
CNP
1
3
SW8SW5
13 13
CN33
ZNR
F
X06
X05
X04
713 5
CND CN90
95
U
1
T
CN3T
31
CNT
2
345
U
6
M
7
CN7V
SWE
50/60Hz
380/400/415V
9
2
1
TH24
CN22
21
M
654321
SW4
X4
X2
52F
X1
F1
SW7 SW2
654321
CN60
X2
3
1
321
CN31
SW11
SW12
SW14
CN7V
6543217
SW3 SW1
SWC
51F
CN31
12
3
Indoor controller board No.1
CN90
CND
CNT
CN60
CN21
CN20
SW5
1
152
2
31 34156
L1
L2
TH22
SW2
SW7
13
CN3T
CN29
TH23
SWC
SW3
CN3A
1
2
SW4
Power supply
3N~
7
X04
X05
X06
F
ZNR
L3
52F
123456
T
CN33
31
CN28
3
1
1
2
M
M
313
121212
X1
3~
X4
51F
SW1
SW8
SWE
5
Remote controller
TB2
1
2
3
4
5
6
7
8
0
9
A
B
C
D
E
F
8
7
6
5
4
3
2
1
0
9
1
2
3
4
5
6
7
8
9
0
TB5
0
9
8
7
6
5
4
3
2
1
9
0
1
2
3
4
5
6
7
8
F
E
D
C
B
A
9
0
8
7
6
5
4
TB15
LCD
TB6
R.B.
3
2
1
Inside section of control box
X1,X2,X4
Fuse<6.3A>F1
F Fuse<6.3A>
Contactor (Fan motor)
Thermistor(Supply air temp. detection)TH21
Electronic linear expan. valve 3LEV3
Electronic linear expan. valve 2LEV2
Symbol Name
Fan motor
Electronic linear expan. valve 1
Remote controller board
Liquid crystal monitor
Power source terminal bed
Transmission terminal bed
Varistor
Transformer
Symbol explanation
MA Remote controller terminal bed
M
R.B.
LCD
TB2
TB5
TB15
ZNR
T
LEV1
Contactor (Fan motor)52F
51F Over current relay(Fan motor)
CN33 Connector(Defrost output)
Thermistor(Piping temp. detection/gas)
Thermistor(Piping temp. detection/liquid)
Thermistor(Outdoor temp. detection)
Switch (For model selection)SW7
SW1
SW14
SW12
SW11
SW4
SW5
SW8
Switch (For model selection)
Switch (Connection No. set)
Switch (For capacity code)
Switch (For four stages demand selection)
Switch (For mode selection)
Switch (2nd digit address set)
Switch (1st digit address set)
SW3
SW2
Switch (For mode selection)
TH22
TH24
TH23
TB6 Terminal bed(Indoor unit)
CN28 Connector(Fan failure)
SWE
SWC
Switch (For trial run)
Switch (For trial run of fan)
Switch (For mode selection)
Earth
(accessory)
Note:7
Note: 1. (Heavy dotted line): Field wiring
2. Have all electric work done by a licensed electrician according to the local regulations.
3. Earth leakage circuit breaker should be set up on the wiring of the power supply.
4. Mark indicates terminal bed, connector.
5. To enable the "auto recovery after power failure" function, set SW1-9 of both No. 1 and No. 2 circuit
boards to ON.
(Factory setting: OFF)
6. Supply air thermistor is built in on the inside of the indoor unit.
A jumper is taped inside the control box without it being connected to the connector.
Plug the jumper into CN20 on No. 1 circuit board when using the supply air temperature to control the
room temperature. Turn SW7-2 of both No. 1 and No. 2 circuit boards on the indoor unit to ON.
7. Indoor unit is supplied with a thermistor.
Install the sensor in the room to properly control the room temperature.