Instruction manual

PARAMETERS
143
Note: 1. One function can be assi
g
ned to two or more terminals. In this case, the terminal inputs are
OR’ed.
2. The speed command priorities are hi
g
her in order of
j
o
g
, multi-speed settin
g
(
RH, RM, RL
)
and
AU.
3. When HC connection
(
inverter operation enable si
g
nal
)
is not selected, the MRS terminal shares
this function.
4. When advanced ma
g
netic flux vector-V/F switch-over and load pattern selection forward/reverse
rotation boost are not selected, the second functions (RT) share these functions.
5. Use common terminals to assign programmed operation group selection, multi-speeds (7
speeds) and remote setting. They cannot be set individually.
(Common terminals are used since these functions are designed for speed setting and need not
be set at the same time.)
6. Stop-on-contact control selection, Pr. 270 = "1 or 3", shares RT with multi-speed settin
g
(
low
speed), and its allocation cannot be changed.
7. When FR-HC connection inverter operation enable
(
X10
)
si
g
nal is not assi
g
ned, the MRS
terminal shares this function.
8. When "7" is set in Pr. 79 and the PU operation external interlock
(
X12
)
si
g
nal is not assi
g
ned, the
MRS signal acts as this function.
9. When the load pattern selection forward/reverse rotation boost
(
X17
)
si
g
nal is not assi
g
ned, the
RT signal shares this function.
10. When advanced ma
g
netic flux vector-V/F switch-over
(
X18
)
si
g
nal is not assi
g
ned, the RT si
g
nal
shares this function.
11. When a stop position is entered externall
y
for orientation control, the FR-A5AX
(
12-bit di
g
ital
input) is required.
12. Made valid when vector control servo lock is set valid.