Instruction manual

PARAMETERS
157
Pr. 4 "multi-seed setting (high speed)"
Pr. 5 "multi-seed setting (middle
speed)"
Pr. 6 "multi-seed setting (low speed)"
Pr. 59 "remote setting function
selection"
Pr. 180 to Pr. 186
(input terminal function selection)
Related parameters
High-speed frequency control (Pr. 271 to Pr. 274)
Pr. 271 "high-speed setting maximum current"
Pr. 272 "mid-speed setting minimum current"
Pr. 273 "current averaging range"
Pr. 274 "current averaging filter constant"
Used to set the current, averaging range, etc. required when "2" or "3" is set in Pr. 270 to select load torque
high-speed frequency control.
Parameter
Number
Factory Setting Setting Range
271 50% 0 to 200%
272 100% 0 to 200%
273 9999 0 to 400Hz, 9999
274 16 1 to 4000
The lift with a light load or without
a load is moved faster than the
lift with a load.
(The output frequency is increased.)
<With high-speed frequency control>
<Without high-speed frequency control>
Whether there is a load or
not, the lift is moved vertically
at the same speed.
Light
Faster
<Wiring example>
·
Sink logic
·
Pr. 186 = 19
R L
1
U
S L
2
V
T L
3
W
MC
STF
SD
NFB
Motor
Power supply
200 to 230VAC or 380 to 480VAC
Start signal
Load torque high-speed
frequency function selection
CS (Note)
Mechanical
brake
Note: The input signal terminal used depends on the Pr. 180 to Pr. 186 settings.