Instruction manual

22
RELAY OUTPUT
4.2 Terminals
*The operation of each relay depends on the output signal selected.
4.3 Parameter List
By installing this plug-in option, the parameters below are extended.
Set the values according to need.
*1 When the FR-A7AR and FR-A7AC (support FR-A700 series only) are mounted to inverter at the same time, Pr.
322 can not be set nor displayed.
*2 For the FR-E700 series only, the initial value of Pr. 322 is "4".
Use Pr. 320 to Pr. 322 to select signals used for relay output. (Refer to page 23, 25 for signal types.)
Terminal Symbol Description
1A Relay RA1's normally open contact terminal
1B Relay RA1's normally closed contact terminal
1C Relay RA1's contact common terminal
2A Relay RA2's normally open contact terminal
2B Relay RA2's normally closed contact terminal
2C Relay RA2's contact common terminal
3A Relay RA3's normally open contact terminal
3B Relay RA3's normally closed contact terminal
3C Relay RA3's contact common terminal
Parameter Number Name Initial Value
320 RA1 output selection 0
321 RA2 output selection 1
322
*1 RA3 output selection 2 (4) *2
REMARKS
When an option alarm ( to ) occurs, all outputs are tuned off.
2A
2B
2C
1A
1B
1C
3A
3B
3C