Specifications

49
OBJECT MAP
7
7.1.2 Class 0x01 Instance 1
(1) Attribute
*1 High byte of hexadecimal word data means integer and low byte means decimal.
For example, when the read data is 0x010A, it means version 1.010.
*2 Bit definition
Bit0: 0 = allocated, 1 = not allocated, Bit2: 0, Bit8: 1 = minor fault occurrence, Bit9: 0, Bit10: 1 = LED is flickering
red, Bit11: 1 = LED is lit red
*3 As the actual data, 0x04, 0x45, 0x37, 0x30, and 0x30 are stored. 0x04 means 4 byte data and the rest means
ASCII code of "E700".
(2) Service
*1 As set in Pr. 75. Refer to the Instruction Manual of the inverter for details of Pr. 75.
*2 If the inverter does not accept the command, neither inverter reset nor all parameter clear will be performed.
Attribute ID Access Description
Data
Length
Attribute Value
1 Get Vendor ID (Mitsubishi electric) Word 161
2 Get Device Type (AC drive) Word 02
3 Get Product Code Word 49
4 Get Revision Struct 1.YYY
*1
5 Get Status Word
*2
6 Get Serial Number
Double
Word
xxxxxxxx
7 Get Product Name (FR-E700) 5 Byte E700
*3
Service Code Symbol Name Setting Range Description
0x05 Reset
Reset
*1
0 Inverter reset *2
1
Inverter reset
after all parameter
clear
*2
0x0E Get Get_Attribute_Single Get Attribute Single