7.3.2 Output Instance 21/Input Instance 71
1. Output Instance 21 (initial value) (Masterinverter)
When using Output Instance 21, set Input Instance to 71.
[Output Instance 21 details]
Byte Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
0 Net Ref Net Ctrl ⎯⎯
Fault
Reset
Run Rev Run Fwd
1
2 Speed reference (low byte)
3 Speed reference (high byte)
Byte0
Bit0 Run Fwd
Forward rotation signal (0: forward rotation off,
1: forward rotation on) Control related
signals
Makes valid when
NetCtrl (Bit5) = "1"
Bit1 Run Rev
Reverse rotation signal (0: reverse rotation off,
1: reverse rotation on)
Bit2 Fault Reset
Reset request at an error occurrence
Valid only at an inverter trip
(0:no function, 1:fault reset request)
Bit5 NetCtrl
Request permission bit of control related signals (Bit0 to Bit2)
0: Control related signals are invalid (It will not function even if a value is
set in each bit.).
1: Control related signals are valid (it will not be reflected to Pr. 338).
Bit6 NetRef
Request permission bit of speed reference (Byte2, Byte3)
0: Speed related data is invalid (it will not function even if a value is set).
1: Speed related data is valid (it will not be reflected to Pr. 339).
Byte2
Byte3
Speed Ref
Speed reference (r/min)
(Refer to page 42 for conversion formula of
speed and frequency.)
Makes valid when
NetRef (Bit6) = "1"